1. Check that the dust cap is placed on the MPE
70 shaft. Mount the coupling for the MPE 70
on the shaft all the way down to the dust cap
and press down for tight contact. Tighten the
set screw according to specification.
2. Mount the bell housing on MPE 70. Secure
nuts with the right torque.
3. Measure the longest distance “A” from top of
bell housing to the buttom of coupling claw.
4. Mount the coupling on motor shaft.
5. Measure from motor flange to the top of the
coupling. That measurement “B” shall be
3 - 5 mm (0.12 - 0.2 inch) shorter the
measurement “A”.
If alternative mounting is required, please con-
tact Danfoss for further information
Note:
Any axial and radial load on the shaft
must be avoided
6. Verify the measurement and secure the coup-
ling with the right torque on the set screw.
Mount the elastic gear ring and mount the
bell housing/MPE 70 on the motor. After
mounting verify the distance between the
coupling hubs to be 3 - 5 mm (0.12 - 0.2 inch)
axial. The check can be done through the
inspection hole of the bell housing.
7. Secure flange bolts with the rigth torque.
4.3 Installing coupling and
bell housing
Dust cap
Содержание MPE 70
Страница 23: ...Appendices Energy Recovery Device MPE 70 Installation Operation and Maintenance Manual hpp danfoss com...
Страница 25: ...Data sheet Energy Recovery Device MPE 70 hpp danfoss com...
Страница 53: ...Parts list Energy recovery device MPE 70 hpp danfoss com...
Страница 56: ...Parts list MPE 70 56 Danfoss DCS im 2022 08 180R9426 AQ367027814446en 000801 IOM MPE 70 3 Exploded view MPE 70...
Страница 58: ...Danfoss DCS im 2022 08 AX367028596447en 000301 58...
Страница 59: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Страница 63: ...63 180R9426 AQ367027814446en 000801 IOM MPE 70 08 2022...