Safety technology: MCB14x Document No.:
MG34Y104
Rev.: 06 23 October 2012 Page 25 of 25
Appendix 1
List of abbreviations used
Abbreviation Abbreviation derived
from
Meaning
A1
+24 V supply voltage
A2
0 V common
Door
Safe input to control protective interlock
Diag
Diagnostic output
ExC
Safe output to drive energy isolator
GND
Earth
0-V common reference potential for all signal and operating
voltages
NC
Normally closed
NC
NO
Normally open
NO
PR_x
Safe input for proximity switch to speed detection
Ramp
Safe output for tripping braking ramp on the inverter
SIL
Safety Integrity Level
Safety Integrity Level
SLS
Safely-Limited Speed
Safely Limited Speed
SMS
Safe Maximum Speed
Maximum velocity to be monitored
SSO
Safe output to enable the protective interlock
SS1
Safe Stop 1 (time-
controlled)
Safe Stop 1 (time & ramp monitored)
STO
Safe Torque Off
Safe Torque Off
ZSP
Zero Speed
(Residual) velocity defined as being at a standstill
Appendix 2:
Content of serial number barcodes
Setup
MCB140:
130B5001xxxxzz-wwy
MCB141
130B6447xxxxyy-wwy
xxxx
Consecutive serial number
zz
Revision information (Rev. A as decimal number in ASCII Code 65)
ww
Production week number
y
Last digit of years
The serial number for MCB140 and MCB141 depends on the option. The serial number is reset to 0100 each
week.
The barcode is an interleaved 2/5 barcode without checksum. This barcode can only show the characters 0-9. All
other characters are replaced by the relevant ASCII Code.
Example:
MCB140 produced in week 33 in 2012:
Serial number
130B5001 010065-332
Barcode equivalent
130665001 01006545332