Safety technology: MCB14x Document No.:
MG34Y104
Rev.: 06 23 October 2012 Page 23 of 25
Parameter description - Group P3
No.
Name
Setting value
Default
Notes
P 301
SS1 Delay time
0….7200s
5
Trip delay delay of O23…O33 outputs
once SS1 is enabled
P 302
Zero Speed Limit
6 …1350 RPM
60
Upper speed limit for standstill
P 303
SLS Speed Limit
Zero Speed + 10%
SMS Speed – 10%
1500
Upper speed limit for operating mode 2
P 304
SMS Speed Limit
SLS Speed + 10%
15000 RPM
12000
Upper speed limit for operating mode 1
Table 24: Parameter group 3
The parameters P302..P304 are only effective if speed detection is enabled (P201 > 0)
Parameter description - Group STORE (Parameter group 4)
Readout
Memory options
Default
Notes
StorE
YES
Yes
Changes are saved
No
Changes are discarded
dEFAULt
All parameters are reset to their default values
Table 25: Parameter group STORE
Overview of input terminal configurations
The following references and signal types are defined:
Mnemonic
Schematic diagram
Notes
Test cycles of Pout_1/2 outputs must be used
Signal antivalence as criterion for short circuit
or crossover
Short circuit and crossover test carried out by
signal reference outputs
Short circuit and crossover test carried out by
signal reference outputs
Test cycles of Pout_1/2 outputs must be used
Short circuit and crossover test of MCB
disabled
Short circuit and crossover test of MCB
disabled
Table 26: Definitions of input switch states which can be set
1
3
0
B
D
8
6
0
.1
0
NC-NC
Pout_1
Pout_2
SS1_1 (SLS_1, Door_1)
SS1_2 (SLS_2, Door_2)
NC-NO
+24V
+24V
SS1_1 (SLS_1, Door_1)
SS1_2 (SLS_2, Door_2)
SS1_1 (SLS_1, Door_1)
SS1_2 (SLS_2, Door_2)
OSSD
SS1_1 (SLS_1, Door_1)
SS1_2 (SLS_2, Door_2)
PNP-NPN
NO-NO
Pout_1
Pout_2
SLS_1
SLS_2
NC-noP
+24V
+24V
SS1_1 (SLS_1, Door_1)
SS1_2 (SLS_2, Door_2)
NO-noP
+24V
+24V
SLS_1
SLS_2
Intr
insically
saf
e
outputs PNP
Intr
insically
saf
e
outputs XOR