Procedure
1. In the panel in the right view, select
PROFINET IO
⇒
Additional Field Devices
⇒
Drives
⇒
VLT FC Series
⇒
Danfoss FC PN
.
e3
0b
e0
80
.1
1
2. Drag the
Danfoss FC PN
module and drop it onto the PROFINET connection. STEP 7 sometimes requires to enter a password for this
operation.
3. In the
Password for Safety Program
dialog box, enter the appropriate password.
4. To edit the Danfoss device properties, double-click the device.
5. In the
Device name
field, enter the same name as shown in
parameter 12-08 Host Name
.
e3
0b
e0
81
.1
1
6. Select the module and add the following I/O protocol:
PROFIsafe 30 -6/6 Bytes, Standard Telegram 30
.
Configuring the Safety Option
Installation Guide | VLT®Safety Option MCB 152
AN327351953089en-000101 / 130R0578| 43
Danfoss A/S © 2020.02