background image

4

WINTER TIME / SUMMER TIME CLOCK

When the clocks are changed from Summer Time to Winter Time (or

vica versa) there is no need to alter the clock by entering programming

mode (i.e. pressing the 

PROG

 button).  Instead just press and hold

down the - button to change from Summer Time to Winter Time or the

+ button to change from Winter Time to Summer Time.  The first time

this is done (after a RESET) the clock is set and can only be changed

by one hour as appropriate.
If a mistake is made, e.g. pressing the + button in the autumn when

the - button should have been pressed, rectify the problem by pressing

the  correct  button  and  then  re-setting  the  clock  by  one  hour  as
appropriate. (Refer to SETTING THE CLOCK on the previous page).

TIME OR TEMPERATURE DISPLAY

The default display in RUN mode shows the time of day.  This may be

changed to display the actual temperature being sensed by pressing

both 

COPY

 and 

NEXT

 buttons together.  Return to time display by

pressing them together again.

THERMOSTAT MODE

The HC75 can be converted to control either heating or cooling, (not

both), at a constant user selected temperature by selecting "Thermostat

mode". To do this, press and hold down both 

and 

t

 buttons until the

display changes to that shown in fig. 6. When entering thermostat

mode the default setting is heating only, with a default temperature of

8°C (46°F ), this can be changed as required by pressing either 

s

 or

t

 until the require temperature is displayed.

To control at a constant cooling temperature (heat off), press the 'SEL'

button to select 'COOL', the temperature will be shown as 28°C (82°F)

(fig. 6a) use the 

s

 and 

t

 buttons to select the required temperature.

When in thermostat mode if "OFF" is selected by means of the 

button, both heating and cooling are turned off.
To return to normal programmed operation, press and hold both 

s

 and

t

.

FROST THERMOSTAT MODE

While  in  thermostat  mode  the  HC75  may  be  set  to  guard  against

possible freeze damage in areas where the unit (or its remote sensor)

is installed. The heating control temperature may be set to a suitable
level using the 

or 

t

 buttons.

HOLIDAY MODE - Heating or Cooling only

While  in  thermostat  mode  with  either  HEAT  or  COOL  selected,

pressing the 

DAY

 button will activate the vacation mode.  The display

will change to that shown in Fig. 7 or Fig. 7a with a number indicating

the default vacation period of 00 days.  Use the + or - buttons to set

the number of days required, in the range 1-99 days.  If the number of

days is left at 00 then the unit will return to normal at event 1 the

following day. When the selected number of days have elapsed the

unit will automatically return to normal, controlling temperatures to the

set program.

Control may also be restored to normal before all days have elapsed

by pressing the 

s

 and 

t

 buttons simultaneously.

USER OVERRIDES

Whilst  the  unit  is  operating  normally  in  RUN  mode  the  following

overrides are available:

TEMPERATURE SETTING OVERRIDE

Press 

s

 to increase or 

t

 to decrease the current set temperatures.

Each press will change the temperature settings by 0.5°C (or 1°F).  To

make  larger  changes  press  the  button  and  hold  it  down.  The

temperatures  can  be  raised  until  the  cooling  temperature  reaches

32°C(90°F) or lowered until the heating temperature reaches 5°C(41°F).

Note  that  the  programmed  dead  band  between  the  heating  and

cooling temperatures is maintained whilst the override is being used.

PROGRAMME OVERRIDE

Whilst running in 

AUTO

 mode both the heating plant and cooling plant

will be switched on and off to maintain the selected temperatures.
The 

SEL

  (select)  button  can  be  used  to  select  one  of  three  other

modes.

AUTO

HEAT

COOL

OFF

AUTO

ON

Fig. 5. Temperature Display.
(Space temperature is below
the set temperature, so the
heating plant and fan are
operating).

Fig. 6. Thermostat mode (Heating)              Fig. 6a Thermostat mode (Cooling)

AUTO

HEAT

COOL

OFF

AUTO

ON

AUTO

HEAT

COOL

OFF

AUTO

ON

28.0°c

8.0°c

Fig. 7 - Heating

Fig. 7A - Cooling

AUTO

HEAT

COOL

OFF

AUTO

ON

AUTO

HEAT

COOL

OFF

AUTO

ON

82.0°F

28.0°c

8.0°c

AUTO

HEAT

COOL

OFF

AUTO

ON

AUTO

HEAT

COOL

OFF

AUTO

ON

Fig. 8. Temperature raised -
heating plant & fan running.

Fig. 9. Temperature lowered -
cooling plant & fan running.

With 

HEAT

 selected only the heating

plant will be controlled, the cooling

plant being switched off.
With 

COOL

 selected only the cooling

plant will be controlled, the heating

plant being switched off.
With 

OFF

 selected both heating and

cooling will be switched off. In this
mode there is no frost protection.

FAN OVERRIDE

Pressing  the  button  marked 

FAN

will switch the fan between 

AUTO,

ON 

and 

SMART

.

AUTO: Thermostat starts fan when

there is a demand for either heating

or cooling.
ON: Fan runs continuously.
SMART:  Fan  runs  continuously

during  events  1-6  unless  a

programmed 'OFF' is encountered, but reverts to Auto mode during

event 6-1. When in 'Smart' mode, the bar on the display adjacent to
FAN ON will flash.

FAN SPEED SELECTION

The slider switch under the flap can be used to select one of three fan
speeds. (A special fan motor is required).

BATTERY MAINTENANCE

Only good quality alkaline batteries should be used.

New batteries will provide the power for switching the outputs on and off for

approximately 2 years. When the batteries volts fall to the minimum level

needed to maintain operation a battery symbol will blink in the display. When

this symbol appears both batteries should be replaced with high quality

alkaline cells. Operation will continue normally until the 15th midnight after

the symbol started blinking and then the unit will switch off all outputs, and

shut down with just the time and the blinking battery displayed. Whilst the

battery symbol is still blinking, the old batteries may be removed and new

batteries placed in the sleeve provided and inserted 

within one minute.

Internal circuitry will maintain the user set programme memory during this

period.

AUTO

HEAT

COOL

OFF

AUTO

ON

AUTO

HEAT

COOL

OFF

AUTO

ON

AUTO

HEAT

COOL

OFF

AUTO

ON

Fig. 11.
Blinking battery symbol, change
batteries.

Part No: 8951  Iss 8  12/01

Danfoss Randall Ltd.

Ampthill Road,
Bedford, MK42 9ER
Tel:  01234 364621 Fax: 01234 219705
email:  [email protected]
Website:  www.danfoss-randall.co.uk

Danfoss Randall Ltd. continually strives to improve its products and
reserves the right to change designs and specifications without notice.

AUTO

HEAT

COOL

OFF

AUTO

ON

AUTO

HEAT

COOL

OFF

AUTO

ON

Отзывы: