Option TADA – Pressure Compensator Over Ride
TA – Pressure Compensator Over Ride / default (high pressure below PCOR pressure = min.
displacement)
DA – with Pressure Compensator Over Ride / without Brake Pressure Defeat
C
Caution
This control is not for use in propel applications.
Hydraulic schematic
B
A
n
N
M4
M5
L2
L1
max
min
MA
MB
P301 327
Where:
A, B
Main pressure lines
L1, L2
Drain lines
M4, M5
Gauge port servo pressure
MA, MB
Gauge port system pressure
N
Speed sensor (optional)
Option TADA
Hydraulic actuator X1
Non-pressurized = min. displacement.
Pressurized = max. displacement.
P301 329
6°
32°
PCOR
160 bar
[2321 psi]
300 bar
[4351 psi]
1
2
3
Default: High pressure below PCOR pressure = min. displacement
Where:
1
Max. displacement
2
Min. displacement
3
Start setting range
Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Controls – nomenclature, description
©
Danfoss | December 2016