Options K1KA, K2KA – electric proportional control with PCOR
K1 – electric proportional 12 V / de-energized = min. displacement / with PCOR
KA – with Pressure Compensator Over Ride / without Brake Pressure Defeat
K2 – electric proportional 24 V / de-energized = min. displacement / with PCOR
KA – with Pressure Compensator Over Ride / without Brake Pressure Defeat
W
Warning
This control is not for use in propel applications.
Hydraulic schematic
B
A
n
N
M4
M5
L2
L1
min
max
C1
MA
MB
P301 463
Where:
A, B
Main pressure lines
L1, L2
Drain lines
M4, M5
Gauge port servo pressure
MA, MB
Gauge port system pressure
N
Speed sensor (optional)
Options K1KA, K2KA
Solenoid C1
De-energized = min. displacement
Full-energized = max. displacement
Displacement (%) versus Input Command (mA)
32°
6°
160 bar
[2321 psi]
300 bar
[4351 psi]
PCOR
0
200
400
600
800
1000
1200
1400
1600
1800
P003 486
K1
K2
mA
0%
20%
40%
60%
80%
100%
Z
K1, K2 = K1, K2 Control
Z = Start setting range
Grey area
= Intended to be used for zero degree capability.
Below are formulas to calculate start and end input command dependent on displacements:
Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Controls – nomenclature, description