![Danfoss H1 Series Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/danfoss/h1-series/h1-series_technical-information_3448078060.webp)
Options T1G1, T2G2 – electric two-position control with PCOR and electric BPD
T1 – electric two-position 12 V / de-energized = min. displacement
G1 – with PCOR / with electric 12 V BPD, de-energized BPD = PCOR active at port B
T2 – electric two-position 24 V / de-energized = min. displacement
G2 – with PCOR / with electric 24 V BPD, de-energized BPD = PCOR active at port B
A
B
n
min
max
C5
C6
M4
MB
M5
P006 067
L1
L2
N
MA
Where:
A, B
Main pressure lines
L1, L2
Drain lines
M4, M5
Gauge port servo pressure
MA, MB
Gauge port system pressure
N
Speed sensor (optional)
Options T1G1, T2G2
Solenoid C6
De-energized = min. displacement
Full-energized = max. displacement
Displacement versus control signal versus PCOR pressure
P003 409
12 V/24 V
6°
32°
PCOR
160 bar
[2321 psi]
300 bar
[4351 psi]
2
1
3
Where:
1
Maximum displacement
2
Minimum displacement
3
Start setting range
Solenoid Data C5 (BPD) and C6 (Two-Position Control)
Description
12 V
24 V
Min. supply voltage
9.5 V
DC
19 V
DC
Max. supply voltage (continuous)
14.6 V
DC
29 V
DC
Nominal coil resistance @ 20 °C [68 °F]
8.4 Ω
34.5 Ω
Recommended input current
1050 mA
500 mA
Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Controls – nomenclature, description
60 |
©
Danfoss | December 2016
11037153 | BC00000043en-US1103