Installation / environment

Step 1:

Position the machine in a clean, dry, level surface in a well 
ventilated area free of combustible material. Keep a clear perimeter 
of 12” on both sides and 6” at rear of machine. Do not place 
anything on top of machine.

Step 2:

Connect to an appropriate power source using a NEMA L6-15, 
2-pole, 3-wire grounding, 15 Amp 230V locking plug and outlet. 
(See Figure 2)

Machine operation

Step 3:

Set the Power On/Off switch and Heater Timer On/Off to the Off 
position before connecting the machine to the power source.  
(See Figure 3)

Figure 2

Figure 3

Содержание FT1555-BM

Страница 1: ...Operator s Manual Danfoss Contamination Control Products FT1555 BM bench mount capping machine...

Страница 2: ...ator s Manual 2023 03 AQ445452814730en 000101 Table of Contents Capabilities 3 Specifications 3 General information 4 Safety information 4 Installation Environment 5 Machine operation 5 Maintenance in...

Страница 3: ...3 Capabilities CapSeal capsules 1 20mm I D through 3 80mm I D Hex fitting sizes 1 2 12mm through 3 78mm Cycle time 2 0 seconds Specifications Dimensions 9 1 2 W by 20 1 2 L by 7 H 241mm W by 520mm L b...

Страница 4: ...w operating instruction could result in serious injury or property damage Prevent Unauthorized Operation Do not permit anyone to operate this machine unless they have thoroughly read and understand th...

Страница 5: ...ted area free of combustible material Keep a clear perimeter of 12 on both sides and 6 at rear of machine Do not place anything on top of machine Step 2 Connect to an appropriate power source using a...

Страница 6: ...ed heat duration allowing for at least five minutes of preheat time See Figure 5 Note White indicator light will illuminate when heater is activated Step 6 Select the proper CapSeal capsule by measuri...

Страница 7: ...7 Installation environment Step 9 Place capsuled hose assembly fitting end against white Heat Shrink Tunnel Plunger and push into heat Shrink Tunnel Plunger about 3 and hold for at least 2 seconds Se...

Страница 8: ...s cleaned every two months at a minimum Step 1 Turn the timer to 0 position and turn off the main power switch and disconnect the FT1555 BM Capping System from the power source See Figure 11 Step 2 Vi...

Страница 9: ...utton head cap screws from the base plate using a 5 32 hex key wrench See Figure 15 Step 6 Remove the switch end plate and inspect the air intake grill for debris Using a coarse brush remove any debri...

Страница 10: ...5 2540BP 17 600 87 to 1 02 22mm to 26mm 28 X 40 X FT1555 2840UP 720 FT1555 2840BP 15 200 94 to 1 14 24mm to 29mm 31 X 33 X FT1555 3133UP 640 FT1555 3133BP 12 240 95 to 1 14 24mm to 29mm 31 X 40 X FT15...

Страница 11: ...R MACHINERY Directive 73 23 EEC 89 336 EEC Manufacturer Ultraclean Technologies Corp Address 746 Shiloh Pike Bridgeton NJ 08302 USA Herewith declares that the Clean Seal System Heat Shrink Machine Mod...

Страница 12: ...FC Danfoss hoses fittings and tooling provide the ultimate fluid conveyance solutions for a variety of equipment and applications around the world We proudly engineer to support a sustainable future...

Отзывы: