Cdd
"
Min. 0 min
Max. 15 min
Default 0 min
Compressor Door Open Delay/Cdd
This parameter sets the delay in minutes before the compressor stops
when the door is opened. If set to zero, the function is disabled.
"
Srt
"
Min. 0 min
Max. 60 min
Default 0 min
System resume after door open
Fan and Compressor resume after cut out by door open.
"
Pod
"
Min. 0 s
Max. 300 s
Default 300 s
Power ON Delay
This is the delay in seconds between power-on and the compressor being
activated.
Depends on the power ON temperature setting as explained below.
"
Pot
"
Min. -100.0°C
Max. 200.0°C
Default -100.0°C
Power ON Temperature
This parameter is used to accelerate the first application test on the
OEM assembly line; if the cabinet temperature is higher than this
parameter the power ON Delay is overruled and the outputs are activated
without delay.
Con
Condenser Protection settings
NOTE: A condensor temperature sensor is required to use these parameters.
Condenser protection is generally used in dusty environments where
the condenser may accumulate a layer of dust or dirt and therefore be
at risk of overheating.
"
CAL
"
Min. 0°C
Max. 200°C
Default 80°C
Condenser Alarm Limit/CAL
This parameter sets the temperature for the condenser at which an alarm
will be generated.
"
CbL
"
Min. 0°C
Max. 200°C
Default 85°C
Condenser Block Limit/CbL
This parameter sets the temperature which if reached will cause the
compressor to switch OFF.
"
CoL
"
Min. 0°C
Max. 200°C
Default 60°C
Condenser OK Limit/CoL
This parameter sets the temperature at which the compressor is
allowed to start again after the temperature set in "
CbL
" above has been
exceeded and the compressor stopped.
"
CLL
"
Min. -100°C
Max. 20°C
Default -5°C
Condenser Low Limit/CLL
This parameter sets the lowest (condenser) temperature at which the
compressor is allowed to start.
diS
Display settings
NOTE: some display parameters can be set in such as way that they
may be illegal in some jurisdictions. Please check local legislation.
"
diC
"
Min. no
Max. yes
Default no
Display intensity auto control
"
no
": display intensity use fixed value.
"
din
"
Min. 2
Max. 10
Default 10
Display Intensity
The controller can have its display intensity (brightness) set in one of
two ways:
A) With a Danfoss ambient light sensor attached, the brightness of the
display is adjusted automatically according to the ambient light level
(see the assignments section).
B) When no ambient light sensor is attached, the display intensity can
be set to a fixed intensity.
Both options are on a scale of 1 to 10, where 10 is the brightest.