2. The electric machine is mounted from its D-end ange (SAE6 transmission housing ange).
SAE6 ywheel housing is required as a mating ange.
3. Align the electric machine with the mating housing alignment. See Chapter
4. Connect the shaft of the electric machine, make sure to use full spline engagement. Lubricate
the spline.
A recommended spline lubricant is a 50/50 compound of a high temperature grease and a molybdenum disulphide
powder. When applied initially and re-applied at proper intervals, it will help prevent fretting corrosion and premature
wear. This lubricant is not soluble in oil and should be used accordingly. Further products which may be recommended
are Molycote, Meta ux, Never Seeze, Optimol and similar.
5.Attach the mounting bolts. For steel housing the minimum lenght of the bolt is 40 mm and for
aluminium housing 45 mm.
EM-PMI240
6. Installation
30 |
©
Danfoss | Produced By: Danfoss Power Solutions | September 2020
| BC355256345493en-000103