5.0 Optional settings
5.1 Network setup
Each network must contain one (and only one) master unit
(MAS).
All other units must be either slave units (SLA) or independ-
•
ent units (ALO).
Independent units in the network will not respond to
•
or send information to a master unit. However, they still
count towards the network maximum of 32 units.
The following settings on all slave units are controlled from
•
the master unit. All other settings must be configured on
each thermostat.
Time
•
Weekday
•
Economy set-back
•
Network cables are unshielded, untwisted, and unpolarised
•
two-wire cables for easy installation.