Do not place the thermostat on the inner 
side of an exterior wall.

Always install the thermostat at least 50 cm. 
from windows and doors.

Do not place the thermostat in a way that it 
will be exposed to direct sunlight.

Note:

 A floor sensor enables a more 

accurate temperature control and is recom-
mended in all floor heating applications 
and 

mandatory

 under wooden floors to 

reduce the risk of over-heating the floor.

•  Place the floor sensor in a conduit in an appropriate 

place where it is not exposed to sunlight or draft from 
door openings.

•  Equally distant and >2cm from two heating cables.
•  The conduit should be flush with the floor surface - 

countersink the conduit if necessary.

•  Route the conduit to the connection box.
•  The bending radius of the conduit must be min 50mm.

Содержание ECtemp 532

Страница 1: ...Danfoss ECtemp 532 Electronic Thermostat Installation Guide electricheating danfoss com...

Страница 2: ......

Страница 3: ...mounted or surface mounted The thermostat has a button for adjusting the temperature setting with a scale from 5 35 C Furthermore it has a LED indicator showing standby periods green light and heating...

Страница 4: ...50 W 230 V cos 0 3 max 1A Sensing units NTC 15kOhm at 25 C Sensing values 0 C 25 C 50 C 42 kOhm 15 kOhm 6 kOhm Hysteresis 0 4 C Ambient temperature 10 to 30 C Frost protection tempera ture 5 C Tempera...

Страница 5: ...ctrical controls for household and similar use EN IEC 60730 1 general EN IEC 60730 2 9 thermostat 1 2 Safety Instructions Make sure the mains supply to the thermostat is turned off before installation...

Страница 6: ...tion switch The sensor is to be considered as live voltage Have this in mind if the sensor must be extended Always connect the thermostat to continuous power supply Do not expose the thermostat to moi...

Страница 7: ...perature control and is recom mended in all floor heating applications and mandatory under wooden floors to reduce the risk of over heating the floor Place the floor sensor in a conduit in an appropri...

Страница 8: ...Follow the steps below to mount the thermostat 1 Open the thermostat devireg 550 3 5 6 2 4 20 30 40 50 Press the release tab in the bottom of the ther mostat using a flat object Carefully detach the...

Страница 9: ...parate connector Note Always install the floor sensor in a conduit in the floor 3 Set the maximum floor temperature between 20 and 50 C by turning the screw with temperature indica tions in the upper...

Страница 10: ...loor temperature is measured where the floor sensor is placed The temperature of the bottom of a wooden floor can be up to 10 degrees higher than the top Floor manufactures often specify the max tempe...

Страница 11: ...oximate setting for 25 C on top surface of floor 0 05 8 mm HDF based laminate 800 kg m 28 C 0 10 14 mm beech parquet 650 800 kg m 31 C 0 13 22 mm solid oak plank 800 kg m 32 C 0 17 Max carpet thick ne...

Страница 12: ...tly and in accordance with the instructions the fault is submitted to the installer or the seller without undue delay and proof of purchase is provided Please note that the WARRANTY CERTIFICATE must b...

Страница 13: ...lation Guide WARRANTY CERTIFICATE The Danfoss warranty is granted to Address Stamp Purchase date Serial number of the product Product Art No Connected output W Installation Date Signature Connection D...

Страница 14: ...Danfoss ECtemp 532 Installation Guide 14 YEAR WARRANTY 5 Disposal Instruction...

Страница 15: ...Danfoss ECtemp 532 08091241 AQ059186456572en 010102 Produced by Danfoss 07 2022 Danfoss A S Nordborgvej 81 6430 Nordborg Syddanmark Denmark...

Страница 16: ...ECtemp 532 ELKO 088L0035 Product documentation Designed in Denmark for Danfoss A S 08091241 5 703466 209004 d k Thermostat Floor Room Sensor 220 240V 50 60Hz 5 to 35 C 15A 3450W 230V IP 31...

Отзывы: