Danfoss ECtemp 532
Installation Guide
10
3
Settings
How to change the minimum and maximum floor
temperatures
1. Remove the adjust-
ment button.
2. Move the pins to the
desired positions.
3. Put the adjustment
button back in place.
devireg™550
3
5
6
2
4
20
30
40
50
Note:
Please be aware of the following:
• T
he floor temperature is measured where the floor
sensor is placed.
• The temperature of the bottom of a wooden floor can
be up to 10 degrees higher than the top.
• Floor manufactures often specify the max tempera-
ture on the top surface of the floor (usually 27-28˚C).
• By default, the maximum floor temperature is set to
35°C.
• Always use a floor sensor or a room + floor sensor
combination to control floor heating. Without a floor
sensor, the temperature control may be less accurate
and you risk overheating the floor.