![background image](http://html1.mh-extra.com/html/danfoss/dhp-al/dhp-al_user-manual_3503119026.webp)
Danfoss – 26
VUBMF102
5 Raise or reduce the value with the up or down buttons. The graph shows how the curve
slope changes.
6 Press the left button three times to exit the menu.
5 .4
Adjusting a specific part of the heat curve
To change a specified part of the heat curve:
1 Press either the right or left button once to open the INFORMATION main menu. The
cursor is in the OPERATION menu option.
2 Press the down button to move the cursor to the HEATCURVE menu option.
3 Open the menu by pressing the right button once. The cursor is at the CURVE value.
4 Select CURVE 5, CURVE 0 or CURVE -5 using the up or down buttons.
5 Open your selection by pressing the right button once.
6 Raise or reduce the value with the up or down buttons.
7 Press the left button three times to exit the menu.
5 .5
Setting MAX and MIN values
To change MIN or MAX:
1 Press either the right or left button once to open the INFORMATION main menu. The
cursor is in the OPERATION menu option.
2 Press the down button to move the cursor to the HEATCURVE menu option.
3 Open the menu by pressing the right button once. The cursor is at the CURVE value.
4 Press the down button to move the cursor to MIN.
5 Open your selection by pressing the right button once. The text row MIN is marked.
6 Raise or reduce the value with the up or down buttons.
7 Press the left button three times to exit the menu.
Repeat the procedure to change the MAX value, but select MAX instead of MIN at step 4.
5 .6
Setting HEATSTOP
To change HEATSTOP:
1 Press either the right or left button once to open the INFORMATION main menu. The
cursor is in the OPERATION menu option.
2 Press the down button to move the cursor to the HEATCURVE menu option.
3 Open the menu by pressing the right button once. The cursor is at the CURVE value.
4 Press the down button to move the cursor to HEATSTOP.
5 Open your selection by pressing the right button once. The text row HEATSTOP is
marked.
6 Raise or reduce the value with the up or down buttons.
7 Press the left button three times to exit the menu.