Danfoss – 20
VUBMF102
3 .2 .3
Sub-menu HEATCURVE
In the HEATCURVE menu the settings that affect the
indoor temperature are made. For further information,
see the “About your heat pump” section.
Menu text
Description
Adjusted by:
CURVE
The set value indicates the supply line
temperature of the water that is trans-
ported to the heating system at an out-
door temperature of 0°C.
By the customer, if
necessary.
MIN
Sets the lowest permitted supply
temperature.
By the customer, if
necessary.
MAX
Sets the highest permitted supply
temperature.
By the customer, if
necessary.
CURVE 5
Used to adjust the heat curve at an
outdoor temperature of +5°C.
By the customer, if
necessary.
CURVE 0
Used to adjust the heat curve at an
outdoor temperature of 0°C.
By the customer, if
necessary.
CURVE - 5
Used to adjust the heat curve at an
outdoor temperature of -5°C.
By the customer, if
necessary.
HEATSTOP
This function stops all production of
heat when the outdoor temperature is
equal to, or higher than, the set heat stop
value.
By the customer, if
necessary.
REDUCTION
The temperature can be lowered using
an outside timer. The control computer
determines the drop.
By the customer, if
necessary.
ROOM FACTOR
(Only displayed if
a Room sensor is
installed.)
Determines how large an impact the
room temperature is to have when calcu-
lating the supply temperature.
Factory setting: 2
(interval: 1 - 5)
(1 = small, 5 = large)
CURVE
MIN
MAX
CURVE 5
CURVE 0
CURVE -5
HEATSTOP
HEATCURVE
40°c
22°c
70°c
0°c
0°c
0°c
17°c