Danfoss – 21
VUBMF102
3 .2 .4
Sub-menu TEMPERATURE
In the TEMPERATURE menu you are able to view the
various temperatures that the installation has had. All
temperatures are stored 100 minutes (factory setting)
back in time so that they can also be displayed in the
form of graphs.
Menu text
Description
Adjusted by:
OUTDOOR
Outdoor temperature
ROOM
If ROOM shows 20°C the heat curve is
unaffected. If ROOM shows higher or
lower, this indicates that the heat curve
has been adjusted up or down to change
the indoor temperature.
By the customer, if
necessary.
SUPPLY PIPE
Shows the actual supply temperature.
(The desired value is shown between
brackets.)
Read the “Regulation information” section
for more information.
(In operating mode ADD.HEAT the stop
temperature for hot water production is
shown in brackets.)
Not adjustable
(The computer calcu-
lates the temperature
required to maintain
the indoor tempera-
ture.)
RETURN PIPE
Shows the read return temperature. (The
highest permitted temperature is shown
between brackets.)
Authorized installer.
Adjusted for each instal-
lation.
HOT WATER
Shows the actual hot water temperature. Not adjustable
INTEGRAL
Heat production is controlled by a
calculated demand that is automati-
cally calculated when the installation
is in operation. The integral is the heat
system’s energy balance.
Read the “Regulation information” section
for more information.
Not adjustable
BRINE OUT
The temperature of the brine circuit
going out from the heat pump.
Not adjustable
BRINE IN
The temperature of the brine circuit
going into the heat pump.
Not adjustable
OUTDOOR
ROOM
SUPPLY PIPE
RETURN PIPE
HOT WATER
INTEGRAL
BRINE OUT
TEMPERATURE
0°c
20°c
38(40)°c
34(48)°c
52°c
-660
-7°c