DEVIreg™ Opti
9
Installation Guide
• The conduit should be flush with the floor surface, coun-
tersink the conduit if necessary and possible.
• Route the conduit to the connection box.
• The bending radius of the conduit must be min 50 mm.
Follow the steps below to mount the thermostat:
1.
Unpack thermostat
2.
Remove the front cover as showed
on Pic. 1.
3.
Connect the thermostat accor-
ding to the connection diagram.
The screen of the heating cable
must be connected to the earth
conductor of the power supply
cable by using a separate con-
nector.
Note:
Always install the floor sensor in a conduit in
the floor.
IP21
0T35
Mains 220-240V~
50Hz
Max Load
13(1) A
Sensor
Danfoss A/S, 6430 Nordborg, Denmark
Ambient Temperature: 0-35°C
Standby maximum 0.5W
Made in P.R.C.
DEVIreg™ Opti
S2 S1
L
N
LOAD
L
LOAD
N
Pic. 1
Pic. 2