DEVIreg™ Opti
21
Installation Guide
Start up wizard:
When first time connecting the thermostat to power, or
by accessing installer menu, following parameters can be
adjusted:
setting the desired value. Push and hold
button, for 2 sec.,
to exit this menu at any time, into a manual operation mode.
No.
Parameter settings
Settings range
Default
P01
Set time (Set Hour)
0 - 24
00:
P02
Set time (Set Minute)
0 - 60
:00
P03
Set weekday
Monday to Sunday
MON
P04
Temperature control mode
01: Room and floor temp.
02: Only floor temp.
03: Only room temp*
2
P05
Max. floor temperature
20-35° C
(only for 01 & 02 in P04)
33
P06
Window open function
0: Disable; 1: Enable;
1
P07
Frost protection funciton
0: Disable; 1: Enable;
1
P08
Set frost protection temp.
5-9° C
5
P09 Set minimum floor temperature
0: Disable; 1: Enable;
0
P10
Minimum floor temperature
18-29° C
23
P11
Startup wizard
0: Disable; 1: Enable;
0