Plug and fitting installation
If any plugs or fittings are removed from the unit during service, install and torque as indicated. The
following drawings are in generic configurations to show item number for wrench size and torque
reference.
D1P 193 TPE2 control plug fittings
G235
G250
F140
F150
G225
F160
G240
G130
G140
Plug fitting reference
Item
Description
Wrench size
Torque
F160
Drain port L1 (M33 x 2)
17 mm hex
68.4-83.6 Nm
G225
Outlet pressure test port MB (M12 x 1.5)
6 mm hex
22.5-27.5 Nm
G230
Bias orifice
3 mm hex
3.6-4.4 Nm
G240
Bias orifice plug (M8 x 1)
4 mm hex
9.9-12.1 Nm
G235
Servo pressure test port M4 (M12 x 1.5)
6 mm hex
22.5-27.5 Nm
G140
Servo orifice
4 mm
3.6-4.4 Nm
F140
Drain port L3 (M33 x 2)
17 mm hex
68.4-83.6 Nm
F150
Drain port L2 (M33 x 2)
17 mm hex
68.4-83.6 Nm
G250
Servo orifice plug (M12 x 1.5)
6 mm hex
22.5-27.5 Nm