
TPSN (130/145)
Measurement Point,
Outlet Pressure Port MB
M12x1.5
0-600 bar
6 mm
22.5 - 27.5 N·m
Power Control Adjusting Screw
4 mm
Load Sensing Adjusting Screw
4 mm
Pressure Compensated
Control Adjusting Screw
4 mm
Power Control Lock Nut
13 mm
21.6 - 24.6 N·m
Pressure Compensated
Control Lock Nut
13 mm
21.6 - 24.6 N·m
Load Sensing Lock Nut
13 mm
21.6 - 24.6 N·m
P400095
TPSN (193/260)
P400255
Measurement Point,
Outlet Pressure Port MB
M12x1.5
0-600 bar
6 mm
22.5 - 27.5 N·m
Power Control
Adjusting Screw
4 mm
Power Control
Lock Nut
13 mm
21.6 - 24.6 N·m
Pressure Compensated
Control Lock Nut
13 mm
21.6 - 24.6 N·m
Pressure Compensated
Control Adjusting Screw
4 mm
Load Sensing
Adjusting Screw
4 mm
Load Sensing Lock Nut
13 mm
21.6 - 24.6 N·m
Please refer to
for information about the other control options.
Service Manual
D1 High Power Open Circuit Pumps Size 65/130/145/193/260
Adjustments
©
Danfoss | July 2019
L1527453 | AX00000292en-CN0201 | 41