Exceeding the permissible values could cause a loss of function, reduced life or the destruction of the
pump.
Do not exceed the values shown in the table above.
D1P fluid specifications
Features
Units
Value
Viscosity
Intermittent
1)
mm
2
/sec
[SUS]
5 [42]
Minimum
7 [49]
Recommended range
16 - 36 [81 - 168]
Maximum (cold start)
2)
1600 [xxxxx]
Temperature range
Minimum (cold start)
2)
°C [°F]
-40 [-40 °F]
Maximum intermittent
1)
115 [239 °F]
3)
Filtration (minimum)
Cleanliness per ISO 4406
Temperature Range: -40 - 90 °C
[-40 - 194°F]
20/18/15
Temperature Range: 90 - 115 °C
[194 - 239°F]
19/17/14
1)
Intermittent = Short term t < 3min per incident.
2)
Cold start = Short term t < 3min, p ≤ 30 bar [435 psi], n ≤ 1000 min
-1
(rpm) , please contact Danfoss Power Solutions
especially when the temperature is below -25 °C [-13 °F].
3)
Must not be exceeded locally either (e.g. in the bearing area) . The temperature in the bearing area is (depending
on pressure and speed ) up to 5 °C [41 °F] higher than the average case drain temperature.
Service Manual
D1 High Power Open Circuit Pumps Size 65/130/145/193/260
Technical specifications
26 |
©
Danfoss | July 2019
L1527453 | AX00000292en-CN0201