
W
Warning
Do not actuate the MOR unless the machine is in a “SAFE” mode. Unintended MOR operation will cause
the pump to go into stroke, use only for diagnosis purposes.
Solenoid Specification
Technical data - Solenoid
Voltage
24V (±20%)
Start current at Vg min.
200 mA
End Current at Vg max.
600 mA
Maximum current
770 mA
Coil Resistance @ 20 °C [70 °F]
22.7 Ω
PWM Range
70~200 Hz
PWM Frequency (preferred)
*
100 Hz
IP Rating (IEC 60 529) + DIN 40 050, part 9
IP 67
IP Rating (IEC 60 529) + DIN 40 050, part 9 with
mating connector
IP 69K
*
PWM signal required for optimum control performance
Mating connector for Solenoid
Description
Ordering Number
Quantity
Mating Connector
DEUTSCH DT06-2S
1
Wedge Lock
DEUTSCH W2S
1
Socket contact (16 and 18 AWG)
DEUTSCH 0462-201-16141
2
Danfoss mating connector kit
K29657
1
The mating connector is not included in the delivery contents, this can be delivered by Danfoss on request.
Compatible PLUS+1
®
controllers(see below):
MC012
L1301095
MC024
L1315302
MC038
11051653
MC050
L1301752
MC088
11006645
For further information:
please visit:
http://www.danfoss.com/Products/MobileElectronics/index.htm
Service Manual
D1 High Power Open Circuit Pumps Size 65/130/145/193/260
Operation
©
Danfoss | July 2019
L1527453 | AX00000292en-CN0201 | 19