CF-RC  Remote  Controller

Select time for the setback program by defining the time periods with 

normal room tem-

perature

, indicated by the black bars above the time line (the periods outside the black 

bars are the setback periods with 

reduced room temperature

).

Set start and end times by means of the left/right selector and by toggling between them 
using the up/down selector (fig. 1- 

/

).

Note:  A period with normal room temperature is removed by setting start and end to the 

same time. The period is recreated by means of the up/down and left/right selectors.

Confirm with 

Ok

 to activate an overview of the created program (the days selected in the 

program are indicated by bold letters). 

Program 1

S

M T W

T

F S

00

06

12

18

24

Activate?

Ok

Cancel

Activate the program with 

Ok

.

Cancel program

A created program can be deleted with the 

Cancel Program

 

menu leading to the over-

view illustrated above.

Note:   In the 

Options

 menu, the created programs (1-3) will be indicated by more distinct 

capitals.

Note:   If you want to override a setback period in a room, you can do so with the

 

Override 

setback

 function in the 

Options

 menu for each room (see chapter 5.1.1).

Setback temperature

In the 

Setback program

 (see chapter 5.2.2), activate the 

Setback temperature

 menu to 

set the room temperature reduction from 1 to 10°C during setback periods. 

Содержание CF-RC

Страница 1: ...088U0221 GB Instruction CF RC Remote Controller...

Страница 2: ...Danfoss Heating Solutions VIUHM602 Danfoss 03 2011 2 Instruction CF RC Remote Controller...

Страница 3: ...Remote Controller has been installed 6 5 Menus 6 5 1 Rooms 6 5 1 1 Select room 6 5 1 2 Options 7 5 2 Program 7 5 2 1 Period program 7 5 2 2 Setback program 8 5 3 Setup 10 5 4 Alarms 11 6 Service Menu...

Страница 4: ...h the up down and left right selectors in combination with the soft keys When the display back light is out the first touch of a button only activates this light 2 Installation 2 1 Preparations Instal...

Страница 5: ...ll menu to create other names When the installation is finished a start up screen with actual time and date will be shown in the display The screen also shows actual temperature in the first room on t...

Страница 6: ...the docking station to a 230 V power supply outlet by means of the trans former power supply plug Place Remote Controller in the docking station Note To extend the transmission range of the CF2 system...

Страница 7: ...able if setback program is activated see chapter 5 2 2 Cooling Disable cooling function for the room option only available when Master Con troller is in cooling mode Heating cooling Set mode Select he...

Страница 8: ...t all rooms are as signed to Zone 1 To move a room to a different zone just allocate it to the desired zone Example Kitchen is moved from Zone 1 to Zone 3 Zone 3 Add room Kitchen 1 Bath room 1 Living...

Страница 9: ...n and left right selectors Confirm with Ok to activate an overview of the created program the days selected in the program are indicated by bold letters Program 1 S M T W T F S 00 06 12 18 24 Activate...

Страница 10: ...nformation about the error causing the alarm and the time for its registration by the system This Alarm log saves the latest alarms for later access and easy system failure identification Start up scr...

Страница 11: ...s as indi cated on the start up screen 16 14 Tue 26 July 05 Kitchen 20 0 C Status Alarm Menu This indication of Alarm on Remote Controller and the indication on Master Controller will continue until t...

Страница 12: ...ator the system is automatically set to PWM regulation Mixed floor and radiator heating can be selected individually for separate rooms Activate Mode rooms to get a list of rooms and select type mode...

Страница 13: ...is 5 min 6 1 5 Heating Cooling Menu Setup Service Heating Cooling Activate Heating Cooling to configure automatic heating cooling mode Select Change to get following configuration options Not used De...

Страница 14: ...hange Back Mode Set the heating cooling mode to Auto Heating or Cooling Master room Select which room should be the Master room Only rooms with a CF RD room thermostat are listed and selectable Neutra...

Страница 15: ...no delay Wireless delay Wireless no delay Change Back The following table list the relay options for different functions default value in Italic Function Relay Option Function Relay Option MC1 Pump No...

Страница 16: ...s with Yes or discard the changes with No 7 Uninstallation Resetting CF RC Remote Controller fig 1 At the same time activate the Soft key 1 the soft key 2 and the down selector Remote Controller reque...

Страница 17: ...test Link to Master Controller E12 The room thermostat in the indicated room has lost the wireless connection to Master Controller Low bat in Room T E13 The battery level of the room Thermostat for th...

Страница 18: ...Danfoss Heating Solutions VIUHM602 Danfoss 03 2011 18 Instruction CF RC Remote Controller Fig 1 Fig 2...

Страница 19: ...19 Danfoss 03 2011 VIUHM602 Danfoss Heating Solutions Instruction CF RC Remote Controller Fig 4 Fig 3...

Страница 20: ...Danfoss Heating Solutions VIUHM602 Danfoss 03 2011 20...

Отзывы: