22 DKDHR
VI.GP.V2.02
Danfoss District Energy
Instructions
Akva Lux II VX2-E
12.2 Akva Lux II VX2-E (ECL 310/A266)
Substation for indirect heating for single-family, semi-detatched and
terraced houses as well as flats. With one heating circuit for radiator or
floor heating and instantaneous domestic hot water heater. Designed
for wall-mounting with connections in top and bottom of substation.
The temperature for the heating circuit is controlled by a Danfoss
ECL 310 controller in combination with an electronic actuator. The
supply temperature is calculated by the controller on basis of the
outdoor temperature.
Please note:
Your substation may look different than the substation shown, as vari-
ants with other components may be supplied.
Instructions for the fitted components will always be supplied to-
gether with the substation.
Heating circuit
The temperature for the heating circuit is controlled electronically by
the Danfoss ECL controller. The supply temperature ist calculated by
the controller on basis of the outdoor temperature.
The ECL Comfort 310 controller is loaded with a selected application
by means of an ECL Application Key (Plug-&-Play). The Application
Key contains information about application, languages and factory
settings.
The controller is factory preset to turn off the heating automatically
in the summer period.
The controller settings can be changed in accordance with the en-
closed producer instructions for the mounted controller.
See ECL Application Key Box with ECL Comfort 210/310 user guide
and mounting guide, for further information.
Control of heating circuit
For control of heating circuit 1 the Akva Lux II VX2-E (ECL 310) is
supplied with a 2-way valve VS 2 and an electrical actuator AMV 150,
which in combination with the ECL controller controls the heating
circuit.
The electrical actuator has undergone a functional test from factory.
In case of operating disturbances the actuator can be closed manu-
ally turning the manual override knob on top of actuator counter-
clockwise.
Please see enclosed instructions,
Electrical actuator AMV 150
2-way valve VS 2
Manual override (AMV 150)
7369267-9 SIBC R&D
EI.97.Q2.00 © Danfoss 12/01
1
INSTRUCTIONS
VS2 2-way
065R9075
065R9075
DN
L (mm)
15
65
20
70
25
75
DN
L
1
(mm)
15
131
20
142
25
159
DN
L
2
(mm)
15
139
20
154
25
159
DN
L
3
(mm)
15
69
20
74
25
79
Instructions
AMV 150
73691180 DH-SMT/SI
VI.KU.N2.1J © Danfoss 01/2008
1
ENglIsh
Actuators for three point control AMV 150
www.danfoss.com
Page 2
DANsK
Motorer til 3-punkts styring AMV 150
www.danfoss.dk
Side 3
DEUTsCh
Stellantriebe für 3-Pkt.- Eingangssignal AMV 150
www.danfoss.de
Seite 3
sVENsKA
Motor för 3-punktsreglering AMV 150
varme.danfoss.se
Sida 4
NEDERlANDs
Servomotor met 3-puntssturing AMV 150
www.danfoss.nl
Pagina 4
lIETUVIŲ K.
Pavaros trijų padėčių valdymui AMV 150
www.danfoss.lt
5 puslapis
lATVIsKI
Motori trīs punktu kontrolei AMV 150
www.danfoss.com
Lpp. 5
MAgYAR
Szelepmozgatók hárompontos szabályozáshoz AMV 150
www.danfoss.com
6. oldal
ČEsKY
Servopohony s tříbodovým regulačním signálem AMV 150
www.danfoss.cz
Strana 6
POlsKI
Siłowniki sterowane sygnałem 3-punktowym AMV 150
www.danfoss.pl
Strona 7
РУССКИЙ
Электроприводы для трехпозиционного регулирования AMV 150
www.danfoss.ru
Страница 7
AMV 150 +
AMV 150 +
AMV 150 +
VS2 (DN 15)
VMV
AVQM (DN 15)
VS 2
Press and hold the button (on
the bottom side of the actuator)
during manual override.
ECL application key