[110] Start
Homing
NOTICE
This option is available only with
software version 48.XX.
Starts the homing function selected in
parameter 17-80 Homing Function
. Must
remain high until homing is done, otherwise
homing is aborted.
[111] Activate
Touch
NOTICE
This option is available only with
software version 48.XX.
Activates the monitoring of the touch sensor
input.
[112] Relative
Position
NOTICE
This option is available only with
software version 48.XX.
This option selects between absolute and
relative positioning. The option is valid for
the next positioning command.
[113] Enable
Reference
NOTICE
This option is available only with
software version 48.XX.
Positioning mode: The frequency converter
activates the selected positioning type and
target and starts the motion towards the new
target. The motion starts either immediately
or when active positioning is completed,
depending on settings of
parameter 17-90 Absolute Position Mode
and
parameter 17-91 Relative Position Mode
.
Synchronization mode: High signal locks the
actual follower position to the actual master
position. The follower starts and catches up
with the master. Low signal stops the
synchronization and the follower makes a
controlled stop.
[114] Sync. to
Pos. Mode
NOTICE
This option is available only with
software version 48.XX.
Select positioning in synchronization mode.
[115] Home
Sensor
NOTICE
This option is available only with
software version 48.XX.
Normally open contact for defining the home
position. The function is defined in
parameter 17-80 Homing Function
.
[116] Home
Sensor Inv.
NOTICE
This option is available only with
software version 48.XX.
Normally closed contact for defining the
home position. The function is defined in
parameter 17-80 Homing Function
.
[117] Touch
Sensor
NOTICE
This option is available only with
software version 48.XX.
Normally open contact. Serves as a reference
for touch probe positioning.
[118] Touch
Sensor Inv
NOTICE
This option is available only with
software version 48.XX.
Normally closed contact. Serves as a
reference for touch probe positioning.
[119] Speed
mode
NOTICE
This option is available only with
software version 48.XX.
Select the speed mode when
[9] Positioning
or
[10] Synchronization
is selected in
parameter 1-00 Configuration Mode
. Speed
reference is set by reference resource 1 or
fieldbus REF1 relative to
parameter 3-03 Maximum Reference
.
[122] Position Vir.
Master.
NOTICE
This option is available only with
software version 48.XX.
Activates position controlled virtual master
when
[10] Synchronization
is selected in
parameter 1-00 Configuration Mode
.
When the option is selected, the following
occurs:
•
Target position is set by Fieldbus
Pos Ref or preset target is as
defined in
parameter 3-20 Preset
Target
.
•
Speed is set relative to
parameter 3-27 Virtual Master Max
Ref
by the source selected in
parameter 3-15 Reference Resource 1
or fieldbus REF1.
•
Acceleration and deceleration is set
as defined in
parameter group 3-6*
Ramp 3
.
[123] Master
Marker
NOTICE
This option is available only with
software version 48.XX.
Normally open contact. Serves as input for
master marker signal during marker synchro-
nization based on the option selected in
parameter 3-33 Sync. Mode & Start Behavior
.
[124] Master
Marker Inv.
NOTICE
This option is available only with
software version 48.XX.
Normally closed contact. Activates master
marker signal for marker synchronization
based on the option selected in
parameter 3-33 Sync. Mode & Start Behavior
.
Programming
VLT
®
Advanced Harmonic Filter AHF 005/AHF 010
44
Danfoss A/S © 05/2019 All rights reserved.
MG80C602
6
6