Danfoss ADAP-KOOL AK-PC 651 Скачать руководство пользователя страница 19

User Guide 

|

 Capacity Controller, AK-PC 651

RS8HA102 | 19

© Danfoss | ADAP-KOOL® | 2015.10  

Connections used in “Quick configurations”

Example of displa

y vie

w

(no 11)

6CD + FS =

 6 c

ompr

essors

, one is dig

ital

,  + one fan is speed c

on

tr

olled

N

o.

Comp

.

D

ispla

y

A

pplic

ation

O

n/off output

PW

M

O

n/off output

A

nalo

g output

Compr

.

Conden.

DO1

DO2

DO3

DO4

DO5

DO6

DO7

DO8

DO9

DO10

DO11

DO12

DO13

DO14

DO15

AO

1

AO

2

AO

3

AO

4

17

Unl

. A

ll

3C2U + FS

3 w

. 2

speed

C1

C1.1

C1.2

C2.1

C2.2

C2.3

C3

C3.1

C3.2

Fan VSD

A

lar

m

F speed

16

Unl

. A

ll

2C2U + 6F

2 w

. 2

6

C1

C1.1

C1.2

C2.1

C2.2

C2.3

Fan 1

Fan 2

Fan 3

Fan 4

Fan 5

Fan 6

A

lar

m

15

Unl

. A

ll

4C1U + FS

4 w

. 1

speed

C1

C1.1

C2

C2.1

C3

C3.1

C4

C4.1

Fan VSD

A

lar

m

F speed

14

Unl

. A

ll

3C1U + 6F

3 w

. 1

6

C1

C1.1

C2

C2.1

C3

C3.1

Fan 1

Fan 2

Fan 3

Fan 4

Fan 5

Fan 6

A

lar

m

13

Unl

. A

ll

2C1U + 4F

2 w

. 1

4

C1

C1.1

C2

C2.1

Fan 1

Fan 2

Fan 3

Fan 4

A

lar

m

12

Dig

i

8CD + FS

8

speed

C1

C2

C3

C4

C1 PWM

C5

C6

C7

C8

Fan VSD

A

lar

m

F speed

11

Dig

i

6CD + FS

6

speed

C1

C2

C3

C4

C1 PWM

C5

C6

Fan VSD

A

lar

m

F speed

10

Dig

i

6CD + 6F

6

6

C1

C2

C3

C4

C1 PWM

C5

C6

Fan 1

Fan 2

Fan 3

Fan 4

Fan 5

Fan 6

A

lar

m

9

Dig

i

4CD + 4F

4

4

C1

C2

C3

C4

C1 PWM

Fan 1

Fan 2

Fan 3

Fan 4

A

lar

m

8

Var

. speed

8CS + FS

8

speed

C1

C2

C3

C4

C5

C6

C7

C8

Fan VSD

A

lar

m

C speed

F speed

7

Var

. speed

6CS + FS

6

speed

C1

C2

C3

C4

C5

C6

Fan VSD

A

lar

m

C speed

F speed

6

Var

. speed

6CS + 6F

6

6

C1

C2

C3

C4

C5

C6

Fan 1

Fan 2

Fan 3

Fan 4

Fan 5

Fan 6

A

lar

m

C speed

5

Var

. Speed

4CS + 4F

4

4

C1

C2

C3

C4

Fan 1

Fan 2

Fan 3

Fan 4

A

lar

m

C speed

4

Single

8C + FS

8

speed

C1

C2

C3

C4

C5

C6

C7

C8

Fan VSD

A

lar

m

F speed

3

Single

6C + FS

6

speed

C1

C2

C3

C4

C5

C6

Fan VSD

A

lar

m

F speed

2

Single

6C + 6F

6

6

C1

C2

C3

C4

C5

C6

Fan 1

Fan 2

Fan 3

Fan 4

Fan 5

Fan 6

A

lar

m

1

Single

4C + 4F

4

4

C1

C2

C3

C4

Fan 1

Fan 2

Fan 3

Fan 4

A

lar

m

0

None

No

A

nalo

g input

O

n/off I

nput

AI1

AI2

AI3

AI4

AI5

AI6

AI7

AI8

AI9

AI10

DI1

DI2

DI3

DI4

DI5

DI6

DI7

DI8

DI9

DI10

DI11

DI12

DI13

DI14

DI15

DI16

DI17

DI18

17

Sc3

Ss

Sd

Po

Pc

C1

C2

C3

Fan saf

et

y

Load shed

Hea

t

16

Sc3

Ss

Sd

Po

Pc

C1

C2

Fan 1

Fan 2

Fan 3

Fan 4

Fan 5

Fan 6

Load shed

Hea

t

15

Sc3

Ss

Sd

Po

Pc

C1

C2

C3

C4

Fan saf

et

y

Load shed

Hea

t

14

Sc3

Ss

Sd

Po

Pc

C1

C2

C3

Fan 1

Fan 2

Fan 3

Fan 4

Fan 5

Fan 6

Load shed

Hea

t

13

Sc3

Ss

Sd

Po

Pc

C1

C2

Fan 1

Fan 2

Fan 3

Fan 4

Load shed

Hea

t

12

Sc3

Ss

Sd

Sd dig

i

Po

Pc

C1

C2

C3

C4

C5

C6

C7

C8

Fan saf

et

y

Load shed

Hea

t

11

Sc3

Ss

Sd

Sd dig

i

Po

Pc

C1

C2

C3

C4

C5

C6

Fan saf

et

y

Load shed

Hea

t

10

Sc3

Ss

Sd

Sd dig

i

Po

Pc

C1

C2

C3

C4

C5

C6

Fan 1

Fan 2

Fan 3

Fan 4

Fan 5

Fan 6

Load shed

Hea

t

9

Sc3

Ss

Sd

Sd dig

i

Po

Pc

C1

C2

C3

C4

Fan 1

Fan 2

Fan 3

Fan 4

Load shed

Hea

t

8

Sc3

Ss

Sd

Po

Pc

C1

C2

C3

C4

C5

C6

C7

C8

Fan saf

et

y

Load shed

Hea

t

7

Sc3

Ss

Sd

Po

Pc

C1

C2

C3

C4

C5

C6

Fan saf

et

y

Load shed

Hea

t

6

Sc3

Ss

Sd

Po

Pc

C1

C2

C3

C4

C5

C6

Fan 1

Fan 2

Fan 3

Fan 4

Fan 5

Fan 6

Load shed

Hea

t

5

Sc3

Ss

Sd

Po

Pc

C1

C2

C3

C4

Fan 1

Fan 2

Fan 3

Fan 4

Load shed

Hea

t

4

Sc3

Ss

Sd

Po

Pc

C1

C2

C3

C4

C5

C6

C7

C8

Fan saf

et

y

Load shed

Hea

t

3

Sc3

Ss

Sd

Po

Pc

C1

C2

C3

C4

C5

C6

Fan saf

et

y

Load shed

Hea

t

2

Sc3

Ss

Sd

Po

Pc

C1

C2

C3

C4

C5

C6

Fan 1

Fan 2

Fan 3

Fan 4

Fan 5

Fan 6

Load shed

Hea

t

1

Sc3

Ss

Sd

Po

Pc

C1

C2

C3

C4

Fan 1

Fan 2

Fan 3

Fan 4

Load shed

Hea

t

0

Содержание ADAP-KOOL AK-PC 651

Страница 1: ...Capacity controller AK PC 651 User Guide ADAP KOOL Refrigeration Control System...

Страница 2: ...matic safety control day night signal etc Relay outputs max 13 pcs Connection of compressors condenser fans Solid state outputs max 2 pcs Control of capacity valve on a Copeland digital scroll Control...

Страница 3: ...one the control ler will cut out or cut in the next compressor in the sequence When further capacity is either cut out or cut in the capacity from the regulating compressor will be modified accordingl...

Страница 4: ...of the following functions Fixed reference Variable reference which follows the outdoor temperature When the outdoor temperature drops the reference will drop by a corresponding amount This variable...

Страница 5: ...scroll a Copeland stream or Bitzer CRII the capacity will be increased so that the compressor can cool down itself The compressors will be stopped if the temperature reaches the set max temperature va...

Страница 6: ...n groups and 1 condenser group Each of the 3 rows above is continued with three additional displays The arrow in the top corner of the display shows the way to the next display in the same area of ope...

Страница 7: ...y None Main Menu The first setting is the Plant type When the Plant type has been selected it will al low several settings to be made For example Continue to the next menus All settings are explained...

Страница 8: ...s Device for configuration of compressor and condenser Select pressure or saturation temperature Can be set during initial set up and must not be subsequently changed Temp press Fac Saturated Night si...

Страница 9: ...suction gas temperature can be read here Superheat The measured superheat can be read here Day Night status The status of the day night function can be read here Load shed The status of the load shed...

Страница 10: ...0 s Fac 120 s Configuration Configuration Control sensor Select the regulating sensor for the suction circuit Pressure transmitter Po Media temperature sensor S4 brine regulation Po is used for safety...

Страница 11: ...ed AI demand Yes No Fac No Ss suction superheat Monitoring of superheat Define whether a signal from a common Ss sensor on the suction line should be received AI demand Yes No Fac No Injection ON fct...

Страница 12: ...Compressor service Compressor service Comp 1 out of service The compressor can be taken out of operation so that the controller regulates without this compressor No Normal regulation Yes Regulating i...

Страница 13: ...uency converter Step on off control of fans will be via relays Variable step The signals are parallel so external wiring can switch over to step e g if the frequency converter fails AO demand Step Spe...

Страница 14: ...is measured in the suction line by Po and Ss Min 0 K Max 20 K Fac 0 K Superheat Max lim Alarm limit for excess superheating Min 20 K Max 80 K Fac 80 K Superheat delay Delay time before alarm is gener...

Страница 15: ...t Set the output to thermostat AI demand Yes No Fac No Thermostat cut in Here set the temperature value at which the thermostat will cut in Min 50 C Max 150 C Fac 5 C Thermostat cut out Here set the t...

Страница 16: ...ation value 10 C Pressure sensors Signal type 0 20mA 4 20mA AKS32 1 5V or AKS32R 10 90 ratiometric of 5 V supply voltage Important Current types must be connected to inputs Al 1 6 Current types must b...

Страница 17: ...ction is on or off Digital inputs 1 18 Status of on off inputs Here you can see the status of the function alarm Analoge outputs 1 4 Status of analogue outputs Here you can see the size of the output...

Страница 18: ...on the next page App no Display Suction group Condenser Speed Digital Scroll Stream CRII 1 step with unloa der Step Speed 17 3C2U FS 3 x 16 2C2U 6F 2 6 15 4C1U FS 4 x 14 3C1U 6F 3 6 13 2C1U 4F 2 4 12...

Страница 19: ...gle 8C FS 8 speed C1 C2 C3 C4 C5 C6 C7 C8 Fan VSD Alarm F speed 3 Single 6C FS 6 speed C1 C2 C3 C4 C5 C6 Fan VSD Alarm F speed 2 Single 6C 6F 6 6 C1 C2 C3 C4 C5 C6 Fan 1 Fan 2 Fan 3 Fan 4 Fan 5 Fan 6...

Страница 20: ...6 Compressor start and unloaders Fans Injection ON Alarm on DO15 Digital inputs DI1 DI18 Compressor safety inputs Fan safety input External main switch start stop HP safety switch LP safety switch Nig...

Страница 21: ...condensing pressure Pc has been violated 3K below safety limit High pressure Pc Critical HP safety switch cutout High safety limit for external high pressure switch has been violated DI input HP switc...

Страница 22: ...oid earth fault current Use double insulated transformer The secondary side must not be earthed Obtain 0 10 volts from terminals N and AO1 respectively N and AO2 PAY ATTENTION TO THE POLARITY of N Mod...

Страница 23: ...riod times as PWM per 100 capacity is delivered when cooling takes place for the whole period An off time is required by the bypass valve within the period and an on time is also permitted There is no...

Страница 24: ...remaining 50 100 for the unloader The unloader is connected to DO5 or DO6 Stream 6 The compressor capacity is distributed by up to 33 for one relay and the remaining 33 100 for the unloader The unload...

Страница 25: ...ed Display output For type MMIGRS2 Data communication Modbus for AK SM 800 Environments 20 60 C During operations 40 70 C During transport 20 80 Rh not condensed No shock influence vibrations Enclosur...

Страница 26: ...amage poor installation or site conditions can give rise to malfunctions of the control system and ultimately lead to a plant breakdown Every possible safeguard is incorporated into our products to pr...

Отзывы: