VLT
®
MICRO
No.
Parameter
Function
Parameter
Factory
Name
Explanation
Value
Setting
13
Deceleration time 2 d0.1 - d600. sec
d10.0
14
S-curve
S-curve
d00 - d07
d00
15
Jog Operation Jog acel/decel time d0.1 - d600. sec
d1.0
16
Setting
Jog frequency
d0.1 - d400. Hz
d6.00
17
Multi-step
Multi-step speed 1
d0.0 - d400. Hz
d0.00
18
Operation
Multi-step speed 2
d0.0 - d400. Hz
d0.00
19
Speeds
Multi-step speed 3
d0.0 - d400. Hz
d0.00
20
Multi-step speed 4
d0.0 - d400. Hz
d0.00
21
Multi-step speed 5
d0.0 - d400. Hz
d0.00
22
Multi-step speed 6
d0.0 - d400. Hz
d0.0
23
Multi-step speed 7
d0.0 - d400. Hz
d0.0
24
REV run
REV run inhibit
d00:REV run enable
d00
inhibit
d01:Rev run disable
25
Over-volt Stall
Over-voltage stall
d00:Disable over-volt stall prevent
d01
Prevention
prevention
d01:Enable over-volt stall prevent
26
Over-current
Over-current stall
d50 - d200%
d170
Stall
prevention (during
Prevention
acceleration)
27
Over-current stall
d50 - d200%
d170
prevention (during
operation)
28
DC Braking
DC braking current d0.0 - d100%
d0.0
29
DC braking time
d0.0 - d5.0 sec
d0.0
during start-up
30
DC braking time
d0.0 - d25.0 sec
d0.0
during stopping
31
DC braking start-up d0.0 - d60.0 Hz
d0.0
frequency
32
Momentary
Momentary power
d00:Operation stops after
d00
Power Loss
loss operation
momentary power loss
Protection
mode selection
d01:Operation continues after
momentary power loss.
Speed search starts with the
frequency reference value.
d02:Operation continues after
momentary power loss.
Speed search starts with the
minimum frequency
63