Specifi cation
Power Supply
230Vac, ± 15%, 50 Hz
Switching Action
1 x SPST, Type 1B
Switch Rating
264Vac, 50/60Hz, 3(1)A
Setting/Running Accuracy
±1 min./month
Power Reserve
Minimum 24 hours
Max. Ambient Temperature
45°C
Dimensions, mm (W, H, D)
102 x 136 x 47
Design Standard
EN 60730-2-7
Control Pollution Situation
Degree 2
Rated Impulse Voltage
2.5kV
Ball Pressure Test
75°C
NB. For FRU units - go straight to point 6.
1.
Loosen the fi xing screw in the base of the unit to release the
Wiring Cover.
2.
Holding the unit face downwards, press fi rmly in the centre of
the wallplate and slide it apart and lift it from the module.
1.0 Installation Overview
2.0 Product Specifi cation
Please Note:
This product should only be installed by a qualifi ed electrician or
competent heating installer and should be in accordance with the
current edition of the IEEE wiring regulations.
3.0 Installation