Temporary User Overrides

Sometimes  you  may  need  to  change  the  way  you  use  your 

timeswitch  temporarily,  i.e  due  to  unusually  cold  weather.  The 

103E5  has  two  convenient  overrides  which  can  be  selected 

without affecting the set programme. 

+1HOUR

Press 

+1HOUR

  once  if  you  need 

an  extra  hour  of 

operation

 

I

f the system is off it will come on for an hour. If it is already 

on  it  will  add  an  extra  hour  so  the  system  stays  on  for  an 

extra hour. 

To cancel the override press +1HOUR again.

AdVAnCE (only during AUTO mode)

Press the 

AdVAnCE

 button once to 

advance to the next 

programmed event.

 

 

If the system is on it will go off. If it is off it will come on. The 

set  programme  will  resume  at  the  next  programmed  ON/

OFF time.

To cancel the override press ADVANCE again.

PROGRAMME

+

-

Override 

buttons

O

verride butt

ons 

Содержание 103E5

Страница 1: ...ry Replacement Units FRU Electronic timeswitch for controlling hot water and heating Certification Mark This product complies with the following EC Directives Electro Magnetic Compatibility Directive...

Страница 2: ...6 9 Replacement 10 11 User What is a timeswitch 12 Your timeswitch 13 Setting the clock 14 Factory preset programmes 15 Setting the programme 24 hour 16 Setting the programme 5 2 day 17 Running the pr...

Страница 3: ...pply 230 Vac 15 50 Hz Switching action 1 x SPST Type 1B Switch rating 264 Vac 50 60Hz 3 1 A Timing Accuracy 1 min month Power Reserve Minimum 14 days Enclosure Rating IP30 Max Ambient Temperature 45 C...

Страница 4: ...plaster box as required Ensure that the screw heads do not protrude beyond the vertical centre rib of the wallplate or this will prevent the module correctly locating onto the wallplate 4 Surface cab...

Страница 5: ...or weekday weekend mode 5 2 day To convert to 5 2 day mode remove the small two way connector from the pins towards the left of the recess on the rear of the module then press the SELECT ADVANCE butto...

Страница 6: ...e 11 When the circuit check has been completed replace the wiring cover and tighten the fixing screw Cut any cable aperture in the wiring cover which may be necessary to accommodate surface mounted ca...

Страница 7: ...ROOM STAT L N BOILER TERMINALS PUMP TERMINALS LINK 103E5 TERMINALS MAINS SUPPLY FUSED 3 AMP 1 2 3 5 6 Typical control of Pump for Central Heating on a Solid Fuel System 1 2 3 5 6 L N MAINS SUPPLY FUSE...

Страница 8: ...ow Voltage System requiring voltage free contacts COM CALL N ROOM STAT L N BOILER TERMINALS L N PUMP TERMINALS L N 103E5 TERMINALS MAINS SUPPLY FUSED 3 AMP 1 2 3 5 6 LINK 1 2 3 5 6 103E5 TERMINALS L N...

Страница 9: ...g 3 port mid position valve 1 2 3 5 6 COM CALL N ROOM STAT INPUT OUTPUT N L L N 103E5 TERMINALS MAINS SUPPLY FUSED 3 AMP COMBI BOILER TERMINALS 103E5 TERMINALS 1 2 3 5 6 MID POSITION VALVE L N L N MAI...

Страница 10: ...3020 4 2 1 7 6 3 5 RANDALL TSR2 4 5 3 1 2 6 7 GRASSLIN 45 45A 45E 4 3 2 1 HORSTMANN 424 EMERALD PEARL AUTO RANGE 4 2 3 N L 1 5 HORSTMANN 423 PEARL EMERALD TOPAZ 4 1 3 N L 2 5 6 SANGAMO S254 Form 2S408...

Страница 11: ...P2 N L SMITHS IND CENTROLLER 30 4 5 3 1 2 6 SMITHS IND CENTROLLER 40 4 5 3 1 2 SWITCHMASTER 300 1 2 4 N L 3 TOWERCHRON TC 7 3 4 2 1 8 9 10 11 VENNER VENNERETTE MKIIA LOAD LINE N L VENNER VENNERETTE M...

Страница 12: ...ct Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time You may be able to temporarily adjust the heating programme for example Overri...

Страница 13: ...together turning them on and off at the same times The 103E5 can provide 3 ON periods and 3 OFF periods each day and can offer either 24 hour control same programme for each day of the week or 5 2 day...

Страница 14: ...y Setting the clock o Press PROGRAMME once o Use and buttons to set the correct time o When time is correct press PROGRAMME again In 24 hour mode this will take you straight to programming mode where...

Страница 15: ...0 30pm 10 30pm N B 2nd ON and 2nd OFF are set to the same time These 2 times are ignored by the programme therefore the heating will just come on once in the morning and once in the evening If you wan...

Страница 16: ...set the time you want your system to first come on in the morning o Press PROGRAMME again to move to the next step Event 2 o Use the and buttons to set the time you want your system to first go off o...

Страница 17: ...ss PROGRAMME again to move to Event 2 o Use the and buttons to set the time you want your system to first go off o Continue using the PROGRAMME and buttons in this way to set the ON OFF times for even...

Страница 18: ...lay will move between ON OFF ALLDAY and AUTO l ON the hot water heating will remain on constantly l OFF the hot water heating will not come on l AUTO the hot water heating will come on and go off acco...

Страница 19: ...on If the system is off it will come on for an hour If it is already on it will add an extra hour so the system stays on for an extra hour To cancel the override press 1HOUR again ADVANCE only during...

Страница 20: ...ays After 15 days without mains power the unit will switch off and two dots will show in the display However all your programmed on off times will be remembered When the mains power is restored the un...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...ng engineer Name Tel For problems relating to your heating controls Visit our website www danfoss randall co uk Email our technical department drl_technical danfoss com Call our technical department 0...

Отзывы: