46
Fahrzeug-/Funktionsdecoder
ab Firmware-Version 1.11
46
Locomotive decoder PD10MU
from firmware version 3.12
Supplement 1: Notes to Function Mapping
If you want to activate a function enter the value of the corresponding output according to the following table. In case you
want to activate several different functions simultanously you must add up the related values.
Output values:
RG
ABL
n.f.
n.f.
AUX2
AUX1
LR
LV
Value
128
64
32
16
8
4
2
1
RG = shunting gear ABL = low beam light n.f. = no function
Example:
F4 should activate the shunting gear and switch on the outputs LV and LR:
LV=1, LR=2, RG=128: so you must enter the value 131 in CV38.
Timer function
(CV117, 118)
Value = 0
The timer is switched off (continuous function)
Value = 1…250
The timer is activated, the coressponding output will be disconnected after the time of:
entered value x 0.1 [sec].