40
Fahrzeug-/Funktionsdecoder
ab Firmware-Version 1.11
40
Locomotive decoder PD10MU
from firmware version 3.12
CV
Name and definition
Range
Standard
49
Impulse width
0 = 1 ms, 1 = 2 ms, 2 = 4 ms, 3 = 8 ms
0-3
1
50
Control variant
0 = defined by CV56 - CV59, 1 = hard, 2 = soft, 3 = very soft
0-3
2
51
Interchange of connections
Bit
Function Value
0........ Motor connections ................................ 1
1........ Light connections .................................. 2
2........ Track connections ................................. 4
0-7
0
52
Dimming LV/LR
0 = dark … 31 = full brightness
0-31
31
53
Dimming low beam light
(see CV156)
0 = dark … 31 = full brightness
0-31
15
54
Dimming AUX1
0 = dark … 31 = full brightness
0-31
31
55
Dimming AUX2
0 = dark … 31 = full brightness
0-31
31
56
Motor control proportional
Only if CV50 = 0, see: www.doehler-haass.de/„Häufige Fragen“ (only in German)
0-7
3
57
Motor control integral
(as CV56)
0-3
3
58
Motor control measurement period
(as CV56)
0-3
1
59
Motor control impulse width
(as CV56)
0-7
3