![Danaher Motion Superior Electric SLO-SYN SS2000MD7 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/danaher-motion/superior-electric-slo-syn-ss2000md7/superior-electric-slo-syn-ss2000md7_installation-instructions-manual_3356481022.webp)
Danaher Motion Superior Electric
Hardware Specifications
SLO-SYN SS2000MD7 & SS2000MD7-128
15
4.8. Indicator Lights
"POWER" LED, Red
Lights when the drive logic power supply is present, indicating that the
drive is energized.
"FAULT" LED, Red
Lights to indicate over current condition. This condition is a result of
motor winding errors or a ground fault.
Lights also indicate the heat sink temperature has exceeded a safe level
for reliable operation.
Recovery from over-current or over-temperature condition requires
removing and then reapplying power.