Danaher Motion Superior Electric
Installation
SLO-SYN SS2000MD7 & SS2000MD7-128
3
3. INSTALLATION
3.1. Mounting
The SLO-SYN drive is mounted by fastening its mounting brackets to a
flat surface (shown below). If the Heat Sink Assembly (part number
221576-001) is mounted against a bulkhead, apply a thin coating to
thermal compound between the heat sink and the mounting surface
before fastening the unit in place. DO NOT use too much thermal
compound. It is better to use too little than too much.
2.50
5.00 REF.
0.48
5.25
1.36
0.25
4.84
0.31 typ
0.66
0.22 typ.
0.31 typ.
5.73
4.84
Case temperature should not 70° C (+158° F). A heat
sink, such as Superior Electric Heat Sink Assembly 221576-001,
must be used when the drive is operated at a current setting of 4
amps or more. In this case, mount the unit upright (with the
cooling fins vertical) or proper cooling will not occur. Airflow
should not be obstructed. Forced air cooling may be required to
maintain temperature within the stated limits.