Danaher Motion Superior Electric
Hardware Specifications
SLO-SYN SS2000MD7 & SS2000MD7-128
11
4.5. Current Settings
The proper current setting for each motor is shown on the individual
torque vs. speed curve. Use this current level to obtain the torque
shown. The access hole for the switches that set the motor current level
is located on the back of the unit (see next figure). Switches 1 through 6
are used to select the current level. Select the desired operating current
by setting the appropriate switch to position 1 (ON). The OFF position
is labeled "0." Only one switch should be ON. If two or more switches
are ON, the one selecting the highest current level is the active switch.
The switch settings are:
Position
Current (amps)
None
1.0
1
2.0
2
3.0
3
4.0*
4
5.0*
5
6.0*
6
7.0*
*
Heat sinking is recommended at current settings of 4 amps or
higher. The drive case temperature MUST NOT exceed 70° C
.
4.6. Step Resolution
The number of pulses per revolution is selected using positions 7 and 8
of the switch described in Section 4.5. The following chart shows the
correct switch setting for each available step resolution.
Switch Position
Step Resolution
Pulses Per Revolution
7
8
MD7
MD7-128
MD7
MD7-128
0
0
1/2
Full
400
200
1
0
1/10
1/16
2,000
3,200
0
1
1/25
1/64
5,000
12,800
1
1
1/100
1/128
20,000
25,600