ACCESSORY INSTALLATION INSTRUCTIONS:
19
Dana Incorporated
IMM-0007EN Pump Drives BZ
To connect to the motor, it is first recommended to use universal joints, couplings and/or elements which can compensate for
misalignments. For mounting accessories, always refer to the manufacturer's handbook.
6.5 ACCESSORY INSTALLATION INSTRUCTIONS:
Pumps Assembly:
While assembling the pumps to the pump drive, the coupling must be lubricated with a generous layer of grease or with a no-
grip lubricant. Carefully insert the motor shaft into the coupling and make sure that the spigot perfectly matches the spigot of
the flange attached to the pump drive. After checking that the pump is properly centered, tighten all the attachment bolts ap-
plying a torque as indicated in the paragraph "Bolt Tightening Torque Table:" page 23.
CAUTION
all pump drives reverse the rotation direction; if the motor rotation is right-hand, the pump rotation will be left-hand.