Dugan Models E-1 and E-1A User Guide
Installation and Configuration
21
Network Reset
Hold down the channel 1
mute
button to set these parameters to their default values:
*xx =
last two digits of serial number, unless 00, then use 100
DHCP On
Turning DHCP on requests that the network assign an IP number to the Model E-1A,
if the network has that capability. To turn DHCP on, hold the channel 2
bypass
but-
ton down.
8- or 16-Channel Mode
These commands only work if the unit is in digital mode.
Move the
ANALOG–DIGITAL
switch to the
DIGITAL
(down) position.
Hold down the channel 4
bypass
button to select 16-channel mode.
Hold down the channel 4
mute
button to select 8-channel mode.
Model E-1
Model E-1A
IP Address
192.168.1.1
192.168.1.xx*
Netmask
255.255.255.0
255.255.255.0
Gateway
192.168.1.254
192.168.1.254
DHCP
off
off