Dugan Models E-1 and E-1A User Guide
20
3.
Use ADAT (Toslink) cables to link units in a ring network (see below).
Note that all
LINK IN
and
OUT
connectors are used to create the ring.
NOTE:
Due to the Model E-1A’s compact size and close spacing of the ADAT connectors, some large
cables may not fit. The maximum cable width is 0.48 in (12 mm).
NOTE:
Linked Model E-1s appear in group a only. Linked Model E-1As can use groups a–c.
Configuration
Power-up Commands
The Model E-1A can execute one of five commands during each power-up. Select the
command by holding down a specific button during the entire power-up process,
which takes just a few seconds. Power-up is complete after the LEDs stop flashing.
To execute more than one command, turn the unit off after it finishes powering up,
and repeat for the next command.
Table 3-1
Power-up commands
*These buttons perform startup commands on the Model E, not the Model E-1A
Reset
Hold down the channel 1
bypass
button to set all parameters to factory default set-
tings and clear label text. We recommend executing this command (just like “zeroing
out” a console) before starting a new installation.
channel 1
channel 2
channel 3*
channel 4
bypass
System Reset
DHCP On
N/A
16 channel mode
mute
Network Reset
N/A
N/A
8 channel mode