Serie "EUR7"
Pagina A - 20
Rev. M - 01
>
V
ENDING SENSOR TEST
(FTCA)
Select this item to test the vending sensor circuit (FTCA).
The following message will appear on the display:
The “Left” and “Righ” parameters indicate the degree of intensity of the light detected by the sensors.
The “Nois” parameter indicates the level of intensity of the noise detected by the sensors.
We
understand the “status” of the FTCA system through these three parameters.
Possible values:
OK+
: The level is good
OK
: The level is fair
OK -
: The level is minimal but sufficient
ERR
: The level is insufficient
If one of the three parameters should be at the “
ERR
” level, the FTCA infrared system will be out of order
and an “OFF L10…” message will be displayed (see OFF message table for details).
When the following message appears on the display:
The following message will appear when the
3
key is pressed:
When the
3
key is pressed it will be possible to carry out a test delivery (sale) on the yy selection.
For each product delivered (sold) a “beep” will be emitted each time an object passes in front of the
sensors and a different value will appear on the display in the “Sens” field; through this information we
understand that the FTCA system works correctly; the higher the number (Sens), the easier it will be for
the FTCA infrared system to detect the delivered product.
Press the 1 and 2
keys to change the selection indicated by the “Mot” parameter.
Press the 6 key to exit the submenu.
Left Nois Righ
OK+ OK+ OK+
Left Nois Righ
OK+ OK+ OK+
FTCA 2 Enabled
Mot:yy Sens:xxx
Programming
Diagnostics
FTCA sens. test
->->->->
Left Nois Righ
OK+ OK+ OK+
3
3