Serie "EUR7"
Pagina A - 14
Rev. M - 01
RFID PARAMETERS
(Visible and programmable only if an „RFID payment system‟ is installed)
To set the parameters of the RFID payment system.
>
RFID
–
P
RICE BRACKET
:
If an RFID payment system is installed in the vending machine, it allows selecting the price bracket to be
associated with this system.
Settable values:
„
Prices-A
‟(Price bracket A), „
Prices-B
‟(Price bracket B).
[ Default:
Prices-A
]
>
RFID
–
M
ACHINE CODES
:
The correct machine codes (Machine code A and B) must be set in the vending machine in order for the
RFID payment system to work correctly. Contact the technical assistance service if problems should arise.
REFRIGERATOR PARAMETERS
(Visible and programmable only with „
Refrigerator
operation‟ other than “OFF”)
>
I
NTERNAL TEMPERATURE READING
:
To read the internal temperature of the vending machine.
[ Read only ]
>
I
NTERNAL TEMPERATURE SETTING
:
To set the internal temperature of the vending machine; Settable values:
0 ÷ 50°
C..
[ Default: 40°C ]
>
N
IGHT
M
ODE INTERNAL TEMPERATURE SETTING
:
(Visible and programmable only with Vivilight Kit installed and “
Refrigerator
operation” other than “Food & Snack”)
This parameter allows setting the internal temperature of the vending machine when the
Night Mode
function is activated.
Settable values:
0 ÷ 50°C
.
The refrigerator temperature raising function is deactivated during the
Night-Mode
period if the parameter
is set to „
0
‟ (Zero) or to a value below the one set as standard internal temperature („
Set Std Temp 1
‟ in the
“
Refrig. Param’s
” menu).
This parameter can also be programmed through the “
Energy Saving
” menu in the “
General Param’s
”.
Refer to the “
Energy Saving
” section for further information on this function.
[ Default: 0°C ]
>
REFRIGERATION UNIT WORKING TEMPERATURE READING
:
(Only visible if 2
nd
refrigerator probe present)
To read the working temperature inside the refrigeration unit evaporator.
[ Read only ]
>
S
AFETY TEMPERATURE
:
(Visible and programmable only with „
Refrigerator operation = Food & Sn
ack‟)
To read the safety temperature for the sale of food products; see the
Overtemperature control
section
and the description of the “
ERR L09
” error message for the description.
Programming
RFID parameter
RFID Price brkt.
Current value
3
Programming
Refrig. Param's
Probe 1 measure
Current value
3
Programming
Refrig. Param's
Probe 1 Temp.set
Current value
3
Programming
Refrig. Param's
Night Mode temp.
Current value
3
Programming
Refrig. Param's
Probe 2 measure
Current value
3