Calibrating Individual Pixels
S
Syntax
ts:
x
Purpose:
ets an individual pixel’s PRNU coefficient.
spc x y i
Syntax Elemen
The pixel column number from
1
to
2352
.
y
1728
.
The pixel row number from
1
to
i
where
Coefficient value in a range from
0
to
12287
PRNU coeff = 1 + (
4096
i
)
Notes:
the camera is using
csn 0
). You must select the
ser coefficient set (
csn 1
) before you can perform PRNU
g
csn 0
. To return the
csn
get csn
.
The
spc
command is not available when
the factory calibrated coefficients (
u
calibration. An error message is returned if you attempt to
perform PRNU calibration when usin
current
number, send the command
Example:
spc 10 50 500
t PRNU Coefficients
Saves the current PRNU coefficients to non-v
Sy
wpc
coefficient set (
csn 1
) before you c
perform PRNU calibration when using
csn 0
current
csn
number, send the command
ge
wpc
t FPN Coefficients
Pu
u m
3.6.6 Saving, Loading and Resetting Coefficients
Saving the Curren
Purpose:
olatile memory.
ntax:
Notes:
The
wpc
command is not available when the camera is using the
factory calibrated coefficients (
csn 0
). You must select the user
an perform PRNU
calibration. An error message is returned if you attempt to
. To return the
t csn
.
Example:
Saving the Curren
rpose:
Saves the current FPN coefficients to non-volatile memory.
Syntax:
wfc
Notes:
The
wfc
command is not available when the camera is using the
factory calibrated coefficients (
csn 0
). Yo
ust select the user
coefficient set (
csn 1
) before you can save FPN coefficients. An
error message is returned if you attempt to save FPN coefficients
when using
csn 0
. To return the current
csn
number, send the
command
get csn
.
Example:
wfc
DALSA 03-32-10121-09