Spyder3 GigE Vision User’s Manual
DALSA 03-032-20027-02
37
27.78
1000
2K 2 Tap
54.1
1000
4k 2 Tap
twSync ns
100
twSYNC_INT
ns
100
(3000*)
For exposure mode
4 this value needs to
be >3000ns other
wise >100ns
tPR
ns
0
twPR_LOW
ns
3000
twPR_HIGH ns
3000
tPR_INT
ns
3000
Table 8: tReadout Values
tREADOUT
Sensor Size
# Taps
Readout Time
1024 1
25600ns
1024
2
12800ns
2048 1
51200ns
2048
2
25600ns
4096
2
Table 9: tOverhead Values
tOVERHEAD
Sensor Size
# Taps
Readout Time
1024
1
725ns
1024 2
450ns
2048
1
1400ns
2048 2
725ns
Overhead Delay
Overhead_Delay can range from 5 to 6
μ
s and depends on the internal operations of your
computer.