To restore the last saved pixel coefficients, use the command
LoadPixelCoefficients
.
Current Session Settings
These are the current operating settings of your camera. To save these settings to non-
volatile memory, use the command
WriteUserSetting
.
Saving and Restoring PRNU and FPN Coefficients
Saving the Current PRNU Coefficients
Saves the current PRNU coefficients. You can save up to four sets of pixel coefficients
WriteFPNCoefficients =
1, 2, 3, 4
4k model
PixelSetSelector =
set 1, set 2, set 3, set 4
WriteFPNCoefficients =
Executes the command.
Saving the Current FPN Coefficients
Saves the current FPN coefficients. You can save up to four sets of pixel coefficients
WriteFPNCoefficients =
1, 2, 3, 4
4k model
PixelSetSelector =
set 1, set 2, set 3, set 4
WriteFPNCoefficients =
Executes the command.
Loading a Saved Set of Coefficients
Loads a saved set of pixel coefficients. A factory calibrated set of coefficients is available.
LoadPixelCoefficients =
0, 1, 2, 3, 4
PixelSetSelector =
set 0, set 1, set 2, set 3, set 4
LoadPixelCoefficients =
Executes the command.
Resetting the Current Pixel Coefficients
Resets the current pixel coefficients to zero. This command does not reset saved
coefficients.
ResetPixelCoefficients
The digital offset is not reset.
Rebooting the Camera
The command
DeviceReset
reboots the camera. The camera starts up with the last
saved settings and the baud rate used before reboot. Previously saved pixel coefficients
are also restored.
Содержание Spyder3 SG-11-01k40-00-R
Страница 14: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 14 ...
Страница 30: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 30 ...
Страница 82: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 82 ...
Страница 88: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 88 ...
Страница 90: ...Spyder3 GigE Vision User Manual 03 032 20027 02 DALSA 90 ...