37
Spyder2 4k User’s Manual
03-032-10195-04
DALSA
Value
Function
0
Disable selected task
1
Enable selected task
Note:
by default all monitoring tasks are enabled except voltage monitoring.
Example: enable all monitoring tasks
wed 0 1
Example: disable EXSYNC presence
wed 3 0
Temperature Measurement
The temperature of the camera can be determined by using the
vt
command. This
command will return the temperature inside the cover in degrees Celsius. For proper
operation, this value should not exceed 75 °C.
Voltage Measurement
The command
vv
checks the camera’s input voltage and internal voltages during power-
up. If they are within the proper range, the camera returns OK>. Otherwise the camera
returns an error message. Note that the voltage measurement feature of the camera
provides only approximate results (typically within 10%). They should not be used to set
the applied voltage to the camera. The purpose of this test is to isolate gross problems
with the supply voltages.
3.19 Rebooting the Camera
The command
rc
reboots the camera. The camera starts up with the last saved settings.
Previously saved pixel coefficients are also restored.
3.20 Setting the Pre-trigger
A pre-trigger may be required for some frame grabbers.
To set the pre-trigger, use the command:
Syntax:
sp
i
Syntax Elements:
i
Pretrigger value from 0 to 15.
Example:
sp 10
Содержание Spyder2 S2-2x-04K40
Страница 10: ...10 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Страница 38: ...38 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Страница 52: ...52 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Страница 56: ...56 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Страница 74: ...74 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Страница 76: ...76 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...