58
•
Appendix A: GenICam Commands
Camera Power-Up Configuration Selection Dialog
CamExp
ert provides a dialog box which combines the menu option used to select the camera’s
power-up state and the options for the user to save or load a camera state as a specific user set
that is retained in the camera’s non
-volatile memory.
Camera Power-up Configuration
The first drop list selects the camera configuration state to load on power-up (see feature
UserSetDefaultSelector
). The user chooses from the factory data set or from one of 16 available
user-saved states.
User Set Configuration Management
The second drop list allows the user to change the camera configuration any time after a power-up
(see feature
UserSetSelector
). To reset the camera to the factory configuration, select
Factory Set
and click Load. To save a current camera configuration, select User Set 1 to 16 and click Save.
Select a saved user set and click Load to restore a saved configuration.