72
•
Operational Reference
Linea Lite GigE Series Camera
Device User ID
DeviceUserID
Feature to store a user-programmable identifier of
up to 15 characters. The default factory setting is
the camera serial number. (RW)
Beginner
Device Built-In Self Test deviceBIST
Command to perform an internal test which will
determine the device status. (W)
Beginner
DFNC
Device Built-In Self Test
Status
deviceBISTStatus
Return the status of the device Built-In Self
Test.(BIST). Possible return values are device-
specific.
Beginner
DFNC
Passed
Passed No failure detected
Firmware update failed
FirmwareUpdateFailure Last firmware update operation failed.
Sensor Initialization
Failure
SensorFailure There was an error initializing the sensor; the
camera may not be able to capture images.
Firmware Error
FirmwareError Firmware encountered an error during streaming.
Unexpected Error
Unexpected_Error Switched to recovery mode due to unexpected
software error.
Device Built-In Self Test
Status All
deviceBISTStatusAll
Return the status of the device Built-In Self Test
(BIST) as a bit field. The meaning for each bit is
device-specific.
Beginner
DFNC
Device Reset
DeviceReset
Resets the device to its power up state. (W)
Beginner
Device Temperature
Selector
DeviceTemperatureSelector
Select the source where the temperature is read.
Beginner
Internal
Internal Read FPGA and / or PHY temperature.
MaxInternal
MaxInternal Records the highest device temperature since
power up. Value is reset on power off.
Device Temperature
DeviceTemperature
The temperature of the selected source in degrees
Celsius
Beginner
DALSA Software
Compatibility
Component List
DALSASoftwareCompatibilityComponentList List the optional Teledyne DALSA software functions
that are supported.
Beginner
TurboDrive 8-bit
requires v8.01
or greater
Compatibility1 Teledyne DALSA Turbo Drive 8-bit (Monochrome or
Bayer) requires Sapera-LT 8.01 or greater.
TurboDrive 10-bit
requires v8.10 or
greater
Compatibility2 Teledyne DALSA Turbo Drive 10-bit (Monochrome
or Bayer) requires Sapera-LT 8.10 or greater.
TurboDrive 12-bit
requires v8.10 or
greater
Compatibility3 Teledyne DALSA Turbo Drive 12-bit (Monochrome
or Bayer) requires Sapera-LT 8.10 or greater.
Multicast requires a
newer version
Compatibility4 Multicast feature support requires a newer version
of Sapera LT than currently installed.
UserSetDefault
Selects the camera configuration set to load and
make active on camera power-up or reset. The
camera configuration sets are stored in camera
non-volatile memory. (RW)
Beginner
None
None Keep Internal configuration.
Factory Setting
Default Load factory default feature settings.
UserSet1
UserSet1 Select the user defined configuration UserSet 1 as
the Power-up Configuration.
UserSet2
UserSet2 Select the user defined configuration UserSet 2 as
the Power-up Configuration.
UserSet3
UserSet3 Select the user defined configuration UserSet 3 as
the Power-up Configuration.
UserSet4
UserSet4 Select the user defined configuration UserSet 4 as
the Power-up Configuration.