Linea Lite GigE Series Camera
Operational Reference
•
79
I/O Control Feature Descriptions
Display Name
Feature & Values
Description
Standard
& View
Trigger Selector
TriggerSelector
Selects which type of trigger to configure with the various
Trigger features.
Beginner
Single Line Trigger (Start)
LineStart Selects a trigger starting the capture of a single line.
Single Frame Trigger(Start)
FrameStart Selects a trigger starting the capture of a single frame.
Frame size is determined by image format feature
“Height”.
MultiFrame Trigger(Start)
FrameBurstStart Selects a trigger to capture multiple frames. The number
of frames is specified by the
TriggerMode
Controls the enable state of the selected trigger.
Beginner
Off
Off The selected trigger is turned off.
On
On The selected trigger is turned active.
Trigger Frames Count
triggerFrameCount
Sets the number of frames to acquire when a valid trigger
is received. This feature is available when the
is set to MultiFrames Trigger.
Beginner
DFNC
Software Trigger
TriggerSoftware
Generate a software command internal trigger
immediately no matter what the
set to.
Beginner
Trigger Source
TriggerSource
Specifies the internal signal or physical input line to use as
the trigger source. The selected trigger must have its
Note, source availability may depend on the
See Input Signals Electrical Specifications.
Beginner
Line 1
Line1 Select Line 1 (and associated I/O control block) to use as
the external trigger source. See
complete list.
Line 2
Line2 Select Line 2 (and associated I/O control block) to use as
the external trigger source. See
complete list.
Line 3
Line3 Select Line 3 (and associated I/O control block) to use as
the external trigger source. See
complete list.
Rotary Encoder
rotaryEncoder1 Select Rotary Encoder to use as the external line trigger
source. (Available for LineStart trigger.)
Timer 1 End Event
Timer1End Select the Timer1End Event as the internal trigger source.
(Available for Single Frame and MultiFrame triggers.)
Counter 1 End Event
Counter1End Select the Counter1End Event as the internal trigger
source. (Available for Single Frame and MultiFrame
triggers.)
Timestamp Modulo Event
timestampModuleEvent Select the Timestamp Modulo Event as the internal trigger
source.
Action 1
Action1 Select the GigE Vision Action Command 1 as the internal
trigger source. This is a broadcast command that multiple
devices can respond to simultaneously. (Available for
Single Frame and MultiFrame triggers.)
Action 2
Action2 Select the GigE Vision Action Command 2 as the internal
trigger source. This is a broadcast command that multiple
devices can respond to simultaneously. (Available for
Single Frame and MultiFrame triggers.)
Trigger Input Line
Activation
TriggerActivation
Select the activation mode for the selected Input Line
trigger source. This is applicable only for external line
input lines.
Beginner
Rising Edge
RisingEdge The trigger is considered valid on the rising edge of the
line source signal (after any processing by the line inverter
module).
Falling Edge
FallingEdge The trigger is considered valid on the falling edge.
Any Edge
AnyEdge The trigger is considered valid on any edge.