![Dalsa Genie Nano Series Скачать руководство пользователя страница 52](http://html.mh-extra.com/html/dalsa/genie-nano-series/genie-nano-series_user-manual_504432052.webp)
50
•
Operational Reference
Nano Series GigE Vision Camera
Display Name
Feature & Values
Description
Device
Version
& View
Counter Selector
counterSelector
Selects the counter to configure.
1.00
Expert
DFNC
Counter 1
Counter1 Select counter 1
Counter mode
counterMode
Selects the counter mode. The selected Counter is
either Active or Disabled. When Disabled, the Counter
can be configured.
1.00
Expert
DFNC
Off
Off The selected Counter is Disabled
Active
Active The selected Counter is Enabled
Counter Status
counterStatus
Returns the current state of the counter.
1.00
Expert
DFNC
Counter Idle
CounterIdle The counter is idle.
The counterStartSource feature is set to off.
Counter Trigger Wait
CounterTriggerWait The counter is waiting for a start trigger.
Counter Active
CounterActive The counter is counting for the specified duration.
Counter Completed
CounterCompleted The counter reached the CounterDuration count.
Counter Overflow
CounterOverflow The counter reached its maximum possible count.
Counter Start Source
counterStartSource
Select the counter start source. Counter increments
from 0 to the value of the counterDuration feature.
1.10
Expert
DFNC
Off
Off Counter is stopped.
Acquisition Start
AcquisitionStart Counter starts on the reception of the Acquisition
Start event.
Acquisition End
AcquisitionEnd Counter starts on the reception of the Acquisition End
event.
Exposure Start
ExposureStart Counter starts on the reception of the Exposure Start
event
Exposure End
ExposureEnd Counter starts on the reception of the Exposure End
event.
Readout Start
ReadoutStart Counter starts on the reception of the Readout Start
event.
Readout End
ReadoutEnd Counter starts on the reception of the Readout End
event.
Frame Start
FrameStart Counter starts on the reception of the Frame Start
event.
Valid Frame Trigger
ValidFrameTrigger Counter starts on the reception of the Valid Frame
Trigger.
Rejected Frame Trigger
InvalidFrameTrigger Counter starts on the reception of the Invalid Frame
Trigger.
Line 1
Line1 Counter starts on the specified transitions on Line 1
See Input Signals Electrical Specifications.
Line 2
Line2 Counter starts on the specified transitions on Line 2
Output 1
Line3 Counts the number of transitions (based on the
counterIncrementalLineActivation feature setting) of
Output 1.
Output 2
Line4 Counts the number of transitions (based on the
counterIncrementalLineActivation feature setting) of
Output 2.
Timer 1 End
Timer1End Counter starts on the reception of the Timer 1 End
event.
Counter 1 End
Counter1End Counter starts on the reception of the Counter 1 End
event.
Counter Start Line
Activation
counterStartLineActivation
Selects the activation mode of the input line trigger
which starts the counter. This is only applicable when
the counterStartSource feature selects a physical
Line.
1.00
Expert
DFNC
Rising Edge
RisingEdge Starts counting on rising edge of the selected Line.
Falling Edge
FallingEdge Starts counting on falling edge of the selected Line.
Содержание Genie Nano Series
Страница 27: ...Nano Series GigE Vision Camera Using Nano with Sapera API 25 ...
Страница 94: ...92 Technical Specifications Nano Series GigE Vision Camera EC FCC Declarations of Conformity Pending ...
Страница 102: ...100 Additional Reference Information Nano Series GigE Vision Camera Cable Assembly G3 AIOC BLUNT2M ...
Страница 103: ...Nano Series GigE Vision Camera Additional Reference Information 101 Cable Assembly G3 AIOC BRKOUT2M ...