Example: CounterStartSource = Line (Edge Base) Example
Countermode=OFF
Counter is
IDLE
CounterEnd Event Generated
CounterStartSource=
Line 1
CounterWait
Start
Counter Register
Countermode=Active
Counter
Completed
CounterResetSource =CounterEnd(Itself)
CounterStartSource= Line (Edge Base ) Example 2
Active
Active
Active
CounterTriggerActivation=
Falling Edge
Counter STATUS
0
12
8
5
10
any Tick in
CounterEventSource
Active
1
1
CounterDuration=12
0
The Second StartSource Pulse is ignored
Содержание Genie Nano-CXP Series
Страница 6: ...4 Contents Genie Nano CXP Series TECHNICAL SUPPORT 104...
Страница 84: ...82 Technical Specifications Genie Nano CXP Series EMC Declaration of Conformity...
Страница 85: ...Genie Nano CXP Series Technical Specifications 83 EU Declaration of Conformity...
Страница 86: ...84 Technical Specifications Genie Nano CXP Series Declaration of REACH...
Страница 95: ...Genie Nano CXP Series Additional Reference Information 93 Cable AssemblyG3 AIOC BLUNT1M...
Страница 96: ...94 Additional Reference Information Genie Nano CXP Series Cable AssemblyG3 AIOC BLUNT2M...
Страница 97: ...Genie Nano CXP Series Additional Reference Information 95...
Страница 98: ...96 Additional Reference Information Genie Nano CXP Series Cable AssemblyG3 AIOC BRKOUT2M...
Страница 99: ...Genie Nano CXP Series Additional Reference Information 97...
Страница 100: ...98 Additional Reference Information Genie Nano CXP Series Nano GenericPowerSupplywith no I O...
Страница 102: ...100 Additional Reference Information Genie Nano CXP Series Cable Assembly Right Angle I O to Euro Block...
Страница 107: ...Genie Nano CXP Series Contact Information 105...