38
Falcon2 4M, 8M, and 12M Camera User's Manual
03-032-20107-01
Teledyne DALSA
Image Format Control
Action
Parameter
Description
Control the size of the transm itted im age
Wid th
Wid th of the im age / area of interest (in
p ixels)
H eight
H eight of the im age in lines
Offset X
Left coord inate of region of interest.
H orizontal offset of the leftm ost p ixel
relative to the active sensor area.
Offset Y
Vertical offset in lines of the u p p erm ost
p ixel relative to the active sensor area.
Pixel Form at
Mono 8 or Mono 10, bit d ep th to Cam era
Link
Pixel Color Filter
Typ e of color filter ap p lied to the im age
Pixel Cod ing
Cod ing of the im age p ixels. Raw d ata is
the native form at of the sensor.
Pixel Size
Bit d ep th to Cam era Link
Action
Parameter
Description
Select an internal test im age
Test Im age
Selector
Grey H orizontal Ram p
Grey Vertical Ram p
Pu rity
Diagonal Ram p
FPN Diagonal Ram p
PRN U
Sensor Static Pattern1
Sensor Dynam ic Pattern1
Static Valu e
FPN Coefficients
Action
Description
Define m u ltip le areas of interest (AOIs)
Prelim inary featu re. See App end ix A for m ore inform ation.
Set Baud Rate
The bau d rate sets the sp eed (in bits p er second —bp s) of the serial com m u nication p ort and is available as
p art of the Serial Port Control p aram eters.
Serial Port Control
Action
Parameter
Description
Control the bau d rate u sed by the
camera’s serial port
Bau d Rate
9600
19200
57600
115200
230400
460800
All manuals and user guides at all-guides.com